Fitted internally this module monitors a suitable
24Vd.c. supply. The module monitors the external
power supply for any fault condition signalled.
The module should be used with an external
power supply when Nickel-Cadmium batteries are
specified.
Product Code
508.014.031
1700 External Power Interface PCB
There are two versions available:- 1.5A or 3.0A
suitable for powering the system and recharging
integral sealed lead-acid batteries. The power
modules are available to suit 110Va.c. or 240Va.c.
mains supply.
Product Codes
508.014.032
1700 1.5 Amp 240V PSU
508.014.033
1700 3 Amp 240V PSU
508.014.036
1700 1.5 Amp 115V PSU
508.014.037
1700 3 Amp 115V PSU
Integral Power Modules
External Power Interface Module
A uniquely flexible series of basic fire controllers.
Covering 4 or more zones of fire detection and
suitable for cost effective protection in a wide
range of building types. Detection, display, alarm,
and extinguishing control, can be tailored to meet
any need.
Technical Information
System 1700 consists of a number of standard
modules, selectively assembled in one of 5
housings which can be flush mounted using the
appropriate kit - to meet any specific customer
requirement within the designed capacity. These
units can be configured to provide fire detection
with local display, remote display, extinguishing
control or any combination of these functions with
integral power units and secondary batteries or
from separate 24Vd.c. power supplies. Alarm
sounder outputs can be commissioned or pre-
programmed for specific building sectors.
Conventional style monitored detector zones,
each consisting of up to 20 standard smoke, heat
detectors or callpoints.
Remote display or control are driven by a
multiplex transmitter/receiver system on a single
pair cable. Each transmitter can feed up to 4
receivers, at a distance of up to 1Km. Display
legends are replaceable. Standard legend is
English or on the reverse Arabic/English, but
blanks are available to suit other customer
requirements.
Features
• Expandable in four zone increments
• Customised by module selection - uniquely
flexible
• Integral battery and charger
• Simple controls
• Local and remote displays
• Easy installation and extension
• Selective sounder operation
• All circuits fault monitored
• Remote signalling output
• Designed for fire alarm systems specified to
BS5839: Part 1:1988
• Proven exceptionally reliable world-wide
Datasheet - Product Code PSF41 “System 1700
Conventional Fire Controller”
Manual - 02A-02-D1 “Fire Detection Manual”
The Alarm Module with Display is the central
control unit driving the sounders and auxiliaries.
The display indicates Power On, Fire or Fault, and
has push-button switches for Evacuate, Silence,
Reset and Lamp Test enabled by a key-switch.
The module also has an integral fire/fault
sounder.
Product Codes
508.014.020
1700 Alarm PCB & Display (see picture)
508.014.050
1700 Alarm Unit Display Dutch TNO
508.014.055
System 1700 Spare Key
Alarm Module with Display
System 1700 (Conventional Control Panel)