Technical information

Page 15
The AUTOCALL TFX-500M, TFX-800M, TFX-500MV
and TFX-800MV comprise the AUTOCALL TFX
family of self contained Fire Alarm Control Panels.
CALL TFX-500M provides up to 198 analogue
addressable initiating and output devices, while
the AUTOCALL TFX-800M expands the capacity to
990 devices. The basic system hardware and
software is common for both AUTOCALL TFX-
500M and TFX-800M, therefore the 500M can be
expanded to 800M on site.
AUTOCALL TFX controls are designed to be used
with conventional or analogue addressable fire
detection devices, in any combination thereof.
Engineered with advanced microprocessor
technology, these fire control panels provide a
dynamic level of applications flexibility. The
exclusive CONSYS software configuration tool for
site specific user programming easily guides the
trained installer through a menu prompted
decision process.
Features
. Conventional and analogue addressable fire
detection
. 198 Analogue addressable initiating and
output devices plus 1600 discrete inputs or
outputs (TFX-500M)
. 990 Analogue addressable initiating and
output devices plus 1100 discrete inputs or
outputs (TFX-800M)
. TFX-500M may be expanded to TFX-800M on
site
. 80 Character LCD display; 40 user defined
message characters
. Power limited, all circuits
. Integral LED zonal or group annunciator
. Degrade mode in TFX-800M operates
evacuation signals if CPU failure occurs before
or during an alarm
. Smoke detector condition monitoring with
automatic environmental compensation
. Individual smoke detector sensitivity selectable
from the operator interface
. Historical event log for view or print
. Fully site programmable
. Solo test and alarm verification per group or
point
. Automatic time control functions with holiday
exceptions
. Six access levels with unique 0911 Fire
Department Access
. Automatic and manual detector sensitivity
adjustment
. Alarm resound by zone or device
. Modular, expandable
. Single, dual and multi-channel voice systems,
25 and 70 VRMS
. Networking capability to the graphical user
interface from any TFX panel.
Listings & Approvals
. UL 864 Listed for Local, Auxiliary, Remote
Station and Proprietary Receiving Station
Service; File S2561
. CSFM No. 7165-0062:161
. MEA No. 415-92-E
. FM ID No. OX2A8.AY
NOTE: AUTOCALL TFX-500M and TFX-800M are
intended for use within a building interior, free from
exposure to moisture, condensation and excessive
dust.
Technical Specification
Temperature Range: 0
o
C to 49
o
C
Relative Humidity: 85% Non Condensing
Loop Styles: NFPA 72 Style 4 and 6. Line
isolators optional for short circuit isolation
Max. Add. Per Loop: 99
Max. Loops Per Sys: 2 (TFX-500M)
10 (TFX-800M
Voltage: 26Vd.c., 300mA
Supervisory Current: 20mA per loop (plus load)
Alarm Current: 24mA per loop (plus load)
Resistance: Max 75 Ohms
Capacitance: Max. 0.5 microfarad (mutual)
Inductance: Max. 1.5 millihenry (total)
Max. Continuous Dis: 6500 feet
Product Codes
557.180.623
TFX-500M 2 loop fire control panel with red
architectural door. Grinnell branded in 3 tier
housing with FCM/OCM and 16 LED indicator.
Supplied complete with 4” shallow backbox.
Other colours and branding available on request.
557.180.624
TFX-800M Fire detection panel with red
architectural door and Grinnell branding in 7 tier
housing with FCM/ODM and 80 LED indicator.
Supplied prebuilt complete with 6” backbox.
Other colours and branding available on request.
Analogue Addressable TFX-500/800 Series
Addressable Fire Systems - UL/FM Approved
557.180.624
The AUTOCALL TFX-400 is a self contained, small
addressable panel in a single cabinet. The
AUTOCALL TFX-400 includes 2 analogue,
addressable signalling line circuits that provide 99
points each.
The AUTOCALL TFX-400 uses proven technology,
used in the TFX-500M and TFX-800M fire alarm
and detection systems. The AUTOCALL TFX-400
is designed to be used with conventional or
analogue, addressable fire detection devices, in
any combination. As a stand alone panel, the
AUTOCALL TFX-400 meets the needs of any
small-to-mid size building or building complex;
networking capability allows the TFX-400 to be
used in larger buildings or building complexes.
Features
. 198 Analogue addressable points
. Fully upgradable
. Ideal for retrofit applications
. System status information at a glance
. One panel size with many features of larger
TFX panels
. Compact cabinet fits between wall studs
. Cabinet space for up to 17 Amp hour battery
. Semiflush or surface mount flexibility
. Low cost
Features - Options
. Remote OCP and virtual front panel
. Networking capability
. Graphical user interface
Listings & Approvals
. UL Listed, File S2561
- Local
- Local with Releasing Device Service
- Auxiliary
- Remote Station (Protected Premises Unit)
Proprietary (Protected Premises Unit)
- Central Station (Protected Premises Unit)
- Fire Alarm Control Unit
- Proprietary Receiving Unit
- Central Station Receiving Unit
. CSFM No. 7165-1493:147
7170-1493:167
Technical Specification
Note: A U T O C A L L T F X-400 is int ended f or u se
within a building interior, free from exposure to
moisture, condensation and excessive dust.
Operating Temp.: 0 to +49
o
C
Humidity: 85% Non-Condensing
Loop Styles: NFPA 72 Style 4 & 6. Line
isolators optional for short
circuit isolation
Max. Add Per Loop: 99
Max Loops per Sys: 2
Operating Voltage: 26Vd.c., 300mA
Supervisory Current: 20mA per loop (plus load)
24mA per loop (plus load)
Resistance: Max. 75Ohms
Capacitance: Max. 0.5 microfarad (mutual)
Inductance: Max. 1.5 millihenry (total)
Product Codes
557.180.625
TFX400 Two loop UL/FM approved fire control
panel. Supplied in grey with Thorn Security
branding.
976422
TXF400 Two loop UL/FM approved fire control
panel. Supplied in red with Grinnell branding.
Analogue Addressable TFX-400 Series
TFX400
557.180.623