Service manual
2 • Specifications
2-10 DM300c/DM400c/DM475 Service Manual (SV61801 Rev. D)
Postage Meter
Maximum
Refill
Amount
$99,999.00
Minimum
Refill
Amount
$1.00
Maximum
Stamp
$99.999
Low Funds
Lockout
Amount
Runs to 0.
Reset Type Postage By Phone®
Modem
refill
Required at install and at inspection due
Power cord Supplied
On/Off
Switch
Yes.
2.5 Equipment
Specifications
Environmental Limits
The printing system is designed to function within the following temperature
and humidity limits:
State Parameter Conditions Max. Wet
Bulb Temp.
Normal
Printing
Temperature 40°F (4°C) minimum, 109°F (43°C)
maximum
Humidity 8% minimum, 95% maximum RH 80°F (27°C)
Storage Temperature 15°F (-9°C) minimum, 120°F (49°C)
maximum
Humidity 5% minimum, 95% maximum RH 85°F (29°C)
Shipping
(Less than
24 hours)
Temperature -40°F (-40°C) minimum, 109°F (43°C)
maximum
Humidity 5% minimum, 100% maximum 85°F (29°C)
NOTE: The operating environment is specified as a room ambient condition. The
internal temperature should not exceed this temperature by more than 5°C.