Service manual
6 • Service Menus
DM300c/DM400c/DM475 Service Manual (SV61801 Rev. D)
6-15
Modem Diagnostics
This item is for Engineering use only.
6.4 Diagnostics
SBR Diagnostics (cont’d)
Reset SBR Status
The SBR Status selection is removed from the Service Menu after you run it
(e.g., after you first install a DM475 machine). The Reset SBR Status allows
you to redo the SBR Setup procedure. The SBR Status selection comes in
handy when you have replaced the WOW width sensors (WS4, WS5, WS6) or
WOW thickness or feed encoders because the program walks you through all
of the test procedures necessary for these components (see section 6.3 for the
actual procedure).
004 14.060 12.625 1 0.316
003 14.050 12.250 1 0.309
002 3.150 8.609 0 0.227
001 3.040 8.605 0 0.227
Last 256 Dimen. Captured
No Weight Length W Thick
( Weight in oz)
[Back] when done
024 4.060 10.000 2 0.090
023 4.060 10.039 2 0.090
022 0.520 5.973 1 0.020
021 0.580 6.012 1 0.020
Last 256 Dimen. Captured
No Weight Length W Thick
( Weight in oz)
[Back] when done
Sequence #
(note the order
goes from bot-
tom to top)
Width Sensor
0= none triggered
1= Sensor 1
2= Sensor 2
3= Sensor 3 (not used in
US models)
Last 256 Dimensions
Lists the weight (oz.), length (inches), and thickness (inches) of the last 256
mail pieces run through the machine. It also provides what width sensor (if
any) was triggered by the mail piece as it went through, and the mail piece
sequence number.