Service manual

6 • Service Menus
6-12 DM300c/DM400c/DM475 Service Manual (SV61801 Rev. D)
6.4 Diagnostics
Feeder/WOW Diagnostics
Motors
Allows you to run either the feeder motor or WOW motor at different speeds
(25%, 50%, 75%, and 100%) to verify if they are functioning. NOTE: In actual
usage, the motor frequently starts and stops (not running continuously as is
done in this test).
Sensors
Displays the current state of the sensor. Depending on the sensor, screen
may show either “Clear” or “Blocked”, or “Open” or “Closed”. For WOW
sensors, it includes the SBR width sensors (WS4, WS5, WS6) and thick-
ness encoder (T1).
Read Encoder
Allows you to rotate the WOW motor feed encoder one full revolution to test
its functionality.
Download Firmware
Reload Profiles
Print Logs
Save Logs to File
These items are for Engineering use only.
Submenu 1 Submenu 2 Submenu 3 Submenu 4
Feeder/WOW
Diagnostics
Motors Feeder Motor Excerciser [Run at different speeds]
WOW Motor Excerciser [Run at different speeds]
Sensors Feeder Sensors [“Clear” or “Blocked”
“Open” or “Closed”]
WOW Sensors [Includes SBR sensors
and encoder]
Read Encoder Feeder Motor [Encoder Status]
WOW Motor [Encoder Status]
Download Firmware [Engineering Only]
Reload Profiles [Engineering Only]
Print Logs [Engineering Only]
Save Logs to File [Engineering Only]
Information
[View only feeder/
WOW numeric info]
PCN Information
Counters
Jam Counters XPT Entry
Length Error
WOW Timeout
Reset Counters