Service manual
6 • Service Menus
6-8 DM300c/DM400c/DM475 Service Manual (SV61801 Rev. D)
7. When complete, the SBR Setup Completed screen appears. Select OK
to continue.
NOTE 2: Run one calibration gauge through the machine, 16 succes-
sive times. You must do each run individually, and it must be with the
same gauge – if you load a stack of 16 calibration gauges, the machine
may give length or width errors during this process.
6. The Length Sensor Calibration screen appears. Place the length cali-
bration gauge on feed deck and adjust the side guide appropriately.
Press Start to continue.
NOTE 1: Make sure you have closed the feeder/WOW cover; otherwise
the transport won't start up when you press the Start key (and no error
message displays).
Please run calibration
gauge 16 times through
system.
Length Sensor
Calibration
[Start] to continue
Calibration in process
Remaining: 16
Waiting to run gauge
◄ Abort
Length Calibration
Length cal. completed.
Calibration successful.
◄ OK
SBR Setup Completed
NOTE 3: If an error occurs or if calibration fails, check the side guide set-
ting to make sure the length calibration gauge is not being skewed when
feeding, then press OK to reattempt the length calibration.
NOTE 4: If you select Abort, you will need to start the SBR setup from
the beginning (see step 1 of this section).
8. Press Home key to exit Service Mode.
6.3 SBR Setup
[DM475]