6.3 SBR Setup
[DM475]
1. At the main Service Menu, select SBR Setup.
NOTE 1: If SBR Setup does not display, see Making SBR Setup Dis-
play in Service Menu on previous page.
NOTE 2: If you exit at any time in the process, you will have to begin again
from this point. You will receive a warning screen before you can exit.
2. The Thickness Sensor Status screen appears. Open the feeder/WOW
cover and raise/lower the leading pair of idler rollers on the WOW up-
per transport (see figure below). This action drives the thickness encod-
er and the value on this screen should change. You are only looking for
a transition here, not a specific value. This verifies the thickness sensor
is working correctly. Press Enter to continue.
NOTE: When the leading pair of idler rollers on the WOW upper trans-
port are down, the thickness should read 0.000 inches. If any other
reading occurs, select "Re-zero sensor" and then recheck.
Raise/lower measurement
ski to check sensor:
0.000 in
Re-zero sensor
Thickness sensor
status
[Enter] to continue
Raising/Lowering Feeder/WOW
Leading Pair of Upper Idler Rollers
Leading Pair
of Idler Rollers
3. The Check Width Sensor Location screen appears. Verify that the val-
ues of sensors 1, 2, and 3 match those shown below. This sets the soft-
ware for the correct values as required by the USPS
®
. Press Enter to
continue.
NOTE 1: If no values are displayed, there may be no rates loaded in the
system.
NOTE 2: These are the correct settings for machines in the US. Other
countries may use different values based on their postal requirements.
See separate document for instructions.
Sensor 1 : 155 mm
Sensor 2 : 304 mm
Sensor 3 : 0 mm
Check Width Sensor
Location
[Enter] to continue
304 mm represents 12", the maximum al-
lowable width for a flat (large envelope) per
USPS regulations
155 mm represents 6-1/8", the maximum
allowable width for a letter per USPS regu-
lations
Sensor 3 is not installed on the DM475 for
the US, so this value will be "0"
SBR Setup is run when you first install a DM475 machine or when you have
replaced the WOW width sensors (WS4, WS5, WS6) or WOW thickness or
feed encoders.
TIP: Access the Ser-
vice Menu by typing
6946 and pressing
Refill Postage key.