Service manual
5 • Removal & Replacement
DM300c/DM400c/DM475 Service Manual (SV61801 Rev. D)
5-53
WOW Section of Feeder/WOW Module (use for DM475)
6. Reassemble using this order, keeping in mind the following:
A. Install the new sensor(s) on metal bar and reinstall metal bar.
B. Reattach opaque lens.
C. Reposition the sensor to its original location. Place pencils into holes
on either side of the sensor, push down, and move it to its respective
setting (see below), using the numbers listed on the opaque cover
as your guide.
5.49 WOW
Width Sensors
(WS4, WS5,
WS6)
D. Plug in machine, and access the Service Menu by typing 6946 and
pressing Refill Postage key. Select WOW Options and navigate to
Width Sensor Status/Adjust Sensitivity screen. Verify that you can
get a blocked and clear reading from the sensors.
E. Reinstall sensor cover starting from the left side, then to the right
side.
Sensor 2 (WS5) - position to 250
Sensor 1 (WS4) - position to 155