User`s manual

INTEG Process Group, Inc.
JNIOR
A Network I/O Resource 54
Cinema.JNIOR Application Manual
1. Barco Digital Projector
Communication Method Ethernet
IP Address Customer Defined
Communications Port 43680 (Barco factory default)
Termination String Optional (default is none required)
Commands Available Lamp On
(For use in a JNIOR Macro) Lamp Off
Open Dowser
Close Dowser
Send Macro
Send
NOTES:
A) The Send Macro command is used to send the actual name of any macro
stored on the Barco projector. When this command is used, the Barco will
execute the named macro.
B) The Send command is used to send an ASCII string or a hexadecimal
string. An ASCII string can contain any character and spaces. The text is
sent as lower case unless the Case Sensitivity key is changed to true
(see section 6.1). A hexadecimal string must start with the letters HEX
and then each hexadecimal character must consist of 2 hex characters
followed by an H. An example is: HEX 4AH 4EH 49H 4FH 52H
(which is JNIOR in ASCII).
2. Christie Digital Projector
Communication Method Ethernet
IP Address Customer Defined
Communications Port 5000 (Christie factory default)
Termination String Optional (default is none required)
Commands Available Lamp On
(For use in a JNIOR Macro) Lamp Off
Open Dowser
Close Dowser
Send
NOTE: The Send
command works the same as described under Barco.