User`s manual
INTEG Process Group, Inc.
JNIOR
A Network I/O Resource 13
Cinema.JNIOR Application Manual
5 Macros Set-up
The Cinema.JNIOR application has the ability to run macros stored on the JNIOR. The
macros can control the JNIOR outputs and interact with connected devices. The
following describes the functionality of the JNIOR macros and provides a brief
description of how they are configured. The macros must be built using the JNIOR
Support Tool. Please consult the JNIOR Support Tool manual for further details.
5.1 Macro Creation
Macros for the JNIOR are configured via the JNIOR Support Tool. A file is created with
a complete list of the all the macros and their associated actions and timing. Only 1
macro file can be utilized on the JNIOR at a time. If more than one macro file is
transferred to the JNIOR, the JNIOR may select the first file found which may or may not
be the one intended for operation.
The macro editor contains three main areas (letters correspond to letters in screen shot):
A) – Action View – used to display and manage actions that can be used in macros
B) – Macro View – used to display and create macros consisting of actions and timing
C) – Macro File Overview – display only – shows all the macros, actions and timing
A
B
C