Specifications
Page44
TheStatusPageshowsthecurrentfaderlevel,thecurrentformat,andabargraphshowingtheaudiooutput
levels,auditoriuminformation,andnetworkinformation.
TheLogPageshowstheJSD100systemlog.
x Thefirstcolumnshowsthelogrecordnumber(0to32,767),theUTCtimeof
theevent,thesourceof
theevent,thetypeofevent,andtheeventdescription.Thelogentriesbelowshowthesystembeing
poweredup.
x Record2showsthecontentsofacoupleprocessorregistersafterreset.
x Record3showsthecauseofthereset.
x Record4
showsthatthesystemconfiguration(equalizationandothersettings)wereloaded.
x Record5showsthecurrentinternaltemperature.Thetemperatureisloggedwhenthesystemis
powereduporwhenthetemperaturechanges10degreesC.
x Record6showsthattheformatselectedonpowerupwasadigitalinput,butnodigitalsignalwas
availableatthattime.Whenadigitalsignalappearsortheformatischanged,theclearingofthe
errorislogged.
x Record7showsafaderchangefromthefrontpanel.
x Record8showsaTCPconnectionfrom192.168.1.70.Suchalog
entryistypicallyaconnectionbythe
GUIorfromautomation.NotethattheIPaddressislogged,associatingthisIPaddresswithTCP9.
LatereventsfromTCP9originatedatthisIPaddress.Record9showsTCP9beingdisconnected,so
192.168.1.70hasdisconnectedfromtheJSD100.Usethepreviousandnextlogpagelinkstostep
backwardandforwardthroughthelog.
TheConfigurationPageshowsthesameauditoriumdataandnetworkdataasthestatuspage.Whenfirst
accessingtheconfigurationpage,youwillbeaskedforausernameandpassword.Theusernameisadmin.
Thedefaultpasswordisultra.Tochangethepassword,enterittwiceatthebottomof
theconfigurationpage,
thenpressthe“SaveNewPassword”button.TheConfigurationPagehasalinktotheUpdateFirmwarepage.
TheUpdateFirmwarePageallowsthefirmwareinthetwoDSPsandthemainprocessor(PIC)tobeupdated.
FirmwareisusuallydeliveredinaSoftwarePackagethat
includesnewversionsofthecodeforeachDSPand
themainprocessor(PIC).Wesuggestmakingtheupdatesinthisorder:DSP2,DSP1,PIC.Lookattheversions
ofeachpieceofcodeinthesoftwarepackage.IfoneoftheversionsisalreadyinstalledintheJSD100,that
portionoftheJSD100doesnotneedtobeupdated.Thecurrentlyinstalledfirmwareversionisshownonthe
Updatebuttonforeachprocessor.
x Selectthedevicetobeupdated:DSP2,DSP1,orthemainprocessor(PIC).Pressthe“Browse”button
toselectthefiletobedownloaded
totheJSD100.Pressthe“Update”button.Duringtheupdate,
thefrontpanelLEDsontheJSD100willflash.Afteranupdateofthemainprocessor,theJSD100
willresettostartexecutingthenewcode.Thebrowserwilldisconnectatthattime.