CCE-100 Closed Caption Encoder 181 Bonetti Drive San Luis Obispo, CA 93401 ph: 805-549-0161 fax: 805-549-0163 e-mail:usl@uslinc.com Website: www.uslinc.
CCE-100 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. CCE-100 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. TABLE OF CONTENTS Safety Instructions........................................................................4 FCC Notice...................................................................................4 Introduction...................................................................................5 SMPTE Captioning.......................................................................
CCE-100 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. CCE-100 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. Introduction Important Safety Instructions 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with a dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
Ultra Stereo Labs, Inc. -6- 1. Power supply, 12VDC, 1.2A. 2. USB data duplicates RS232. Used for debug and configuration. 3. Ethernet. Connect to Digital Cinema Server control network. 4. Restore button. Use a paperclip to press button during powerup to restore original firmware and default configuration. 5. RS232 port. Connect Rear Window ® display or use null modem cable to connect a terminal for debug and configuration. 6. RF to IRC-28.
CCE-100 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. CCE-100 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. Click “System Configuration” to get to the configuration screen. You will be prompted for a username and password. The username is admin and the password is ultra. A configuration screen similar to that below should appear. System Installation 1. Choose a location for the CCE-100. The CCE-100 may be rack mounted if the optional rack mount adapter (USL PN: DAX-RAX), was supplied.
CCE-100 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. Starting on the left side of the screen, configure the system using these steps: 1. Set the DCS IP address. This is the Digital Cinema Server IP address the CCE-100 will use to get data from the DCS. 2. Set the timeline offset to 0 Edit Units. If desired, this can be changed to make captions earlier or later. A positive number makes captions appear earlier. 3. Set the caption protocol to SMPTE.
CCE-100 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. CCE-100 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. System Status Page A System Status page is available from the selections at the top of the configuration page. This page shows the last 10 log entries. However, the streaming log, described below, is more useful. Update Firmware Page An Update Firmware page is available from the selections at the top of the configuration page. Use this page to load new firmware into the CCE-100.
CCE-100 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. Viewing an RPL If captions do not run, it is possible that the content does not have captions or the DCS is unable to decrypt the captions. Click the “Last RPL URL” link on the CCE-100 main page. You should see the Auxiliary Resource Presentation List supplied by the DCS. A portion of a typical RPL is shown below. CCE-100 INSTRUCTION MANUAL Ultra Stereo Labs, Inc.
CCE-100 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. Viewing Caption Data The CCE-100 main page includes links to real time captions for each of the three language streams. When the CCE-100 identifies languages in an RPL, the language codes and their stream assignments are shown in the table at the top of the main page. In the screen capture shown above, stream 0 is assigned to U.S. English, and stream 1 is assigned to Spanish. Stream 2 is unused since the RPL only had two languages.
CCE-100 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. - 18 - CCE-100 INSTRUCTION MANUAL Ultra Stereo Labs, Inc.
181 Bonetti Drive San Luis Obispo, CA 93401 ph: 805-549-0161 fax: 805-549-0163 e-mail:usl@uslinc.com Website: www.uslinc.