Owner manual

30 USG Exterior Ceiling Applications
ZXLA with Sheetrock
Lay-In Ceiling Panel
ClimaPlus
28 x 48 System
48" o.c.
12"
max.
12" max.
24" o.c.
Perimeter Conditions
hold-down nail to prevent panel uplift
(see accompanying section detail)
12 ga. hanger wire
pop rivet or MAC2
molding attachment clip
M7Z molding
ZXLA main tee
compression post
12" max.
Sheetrock
Lay-In
Ceiling Panel
ClimaPlus
screw attached
wall molding
Hold-Down Nail
tee
min. 6d common hold-down
nails or similar device shall
inserted in alternating directions
Sheetrock
Lay-In
Ceiling Panel
ClimaPlus
Main Tees: 24 in. o.c.
Cross Tees: 48 in. o.c.
Compression Posts: 24 in. o.c.
Hanger & Compression Post
ZXLA26 (Heavy Duty Main Tee)
ZXLA224 (24 in. Cross Tee)
Hold-Down Nail
UL 1897
85 psf
Note: Pop rivets shall be suitable for exterior use.