Owner manual
22 USG Exterior Ceiling Applications
Celebration
24" o.c.
12"
max.
12" max.
24" o.c.
Perimeter Conditions
12 ga. hanger wire
Celebration
perimeter panel
U-2-3/32 hold down clip
min. 2 per perimeter panel
U-2-3/32 molding
DXFEVH F
INELINE main tee
compression post
12" max.
arrowhead spacer for
cut perimeter panels
into first reveal row
Note: U-2-3/32 molding is designed to receive the perimeter tees and the tee ends are not cut back at an angle.
Back blocking is not required. Fastener attachment through the top leg of molding inth the tee bulb is required.
Item Number Commodity Code
Hold-Down Clip
U-2-3/32HDC 903046
Channel Molding
U-2-3/32 907947
Main Tees: 24 in. o.c.
Cross Tees: 24 in. o.c.
Compression Posts: 24 in. o.c.
Hanger & Compression Post
DXFEVH2924 (Heavy Duty Main Tee)
DXFEV229 (24 in. Cross Tee)
Note: Celebration panels cannot be
installed across a main tee.
UL 580
Class 90