IP
60 Channels
Channel Value Description
1 LED 1 000~255 red (0~100%)
2 LED 1 000~255 green (0~100%)
3 LED 1 000~255 blue (0~100%)
4 LED 1 000~255 white (0~100%)
5 LED 2 000~255 red (0~100%)
... ... ...
57 LED 15 000~255 red (0~100%)
58 LED 15 000~255 green (0~100%)
59 LED 15 000~255 blue (0~100%)
60 LED 15 000~255 white (0~100%)
Master dimmer
Channel 1 controls the intensity of the currently projected colour. When the control knob is in the
highest position (255), the colour intensity is at its highest.
Red-, green-, blue- and white-colour selection
• Channels 2, 3, 4 and 5 control the degree of intensity of the red, green, blue and white LEDs.
• Channels 1, 2, 3, 4 and 5 can be used in combination.
Colour macros
• The required colour-macro is selected with channel 6.
• Channel 6 has priority over channels 2, 3, 4 and 5. Select the intensity of the current
colour-macro with channel 1
Strobe
• Channel 7 controls strobe for channels 1-6.
• Channel 7 has priority over channels 2-5.
• The pulse frequency of the strobe can be set between 0 Hz and 20Hz.
Module selection
Channel 8 oers individual control of the three LED-modules in each fixture.
Channels 245 - 255 change to 11 CH-2-MODE.
4. INSTRUCTIONS