System Initialization
When power is first supplied, the valve may take up to two minutes to initialize the valve.
During this time the valve will show “INTIALIZING WAIT PLEASE”. Do not touch any but-
tons at this time. One beep signals the valve has reached the service position. it will dis-
play the current date and time.
Manual Regeneration (Immediate or Delayed)
1. If screen is locked, press MENU for 3 seconds to unlock. Press MENU again to enter level
one programming mode and adjust CURRENT TIME.
2. Press SET/REGEN to adjust hours. When you have entered the change value mode, the
curser will blink. Press UP OR DOWN arrows to change the hour values. Press SET/
REGEN again to accept the hour value and advance to change the minutes value. Press
UP OR DOWN arrows to change the minute values. Press SET/REGEN again to accept
the minute values and advance to adjust the AM/PM values. Press UP OR DOWN to
change the AM/PM value. Press SET/REGEN again to accept the AM/PM value and exit.
When you have exited the change value mode, the curser will stop flashing.
Setting Current Time
If screen is locked, press MENU for 3 seconds to unlock. To initiate an Immediate Regen-
eration, press the SET / REGEN button for 3 seconds, an option for Delayed or Immediate
Regeneration will appear. Press the SET / REGEN button again and delayed will begin flash-
ing, press the down arrow button to have Immediate flash, press the SET / REGEN button
and then press the MENU button and the valve will immediately start into manual regenera-
tion.
To initiate a Delayed Regeneration, press the SET / REGEN button for 3 seconds, then press
the menu button and a regeneration will be queued to the next pre-set regeneration time
(2:00 a.m.).
1. Press DOWN to advance to CURRENT DATE.
2. Using the same procedure as setting the time, press SET/REGEN to enter value change
mode.
Setting Current Date
1. Press DOWN to advance to NUMBER PEOPLE.
2. Press the SET/REGEN to change the value. Press UP OR DOWN to change the values.
Setting Number of People in Household
1. Press DOWN to advance to WATER HARDNESS.
2. Press the SET/REGEN to change the value. Press UP OR DOWN to change the values.