Specifications

11
11
For emergency needs, hard water is available to the home during the regeneration cycles.
However, you should avoid using HOT water because the water heater will refill with the
hard water.
Automatic Hard Water Bypass During Regeneration
System Configuration
Change Valve Cycle Settings
Valve Set-up
1. If screen is locked, press MENU for 3 seconds to unlock.
2. Press and hold UP AND DOWN for three seconds to enter Level Two Master Program-
ming.
3. Press the DOWN and advance to the BACKWASH menu option. Press SET/REGEN to edit
the BACKWASH minutes. Press UP OR DOWN arrows to change the BACKWASH minute
values. Press SET/REGEN again to accept the new value.
4. Press the DOWN twice to advance to the RINSE menu option. Press SET/REGEN to edit
the RINSE minutes. Press UP OR DOWN arrows to change the RINSE minute values.
Press SET/REGEN again to accept the new value.
5. Press MENU to exit programming mode.
Change Efficiency Settings
1. If screen is locked, press MENU for 3 seconds to unlock.
2. Press and hold UP AND DOWN for three seconds to enter Level Two Master Program-
ming.
3. Press the DOWN and advance to the SALT SETTING menu option. Press SET/REGEN to
edit the SALT SETTING. Press UP OR DOWN arrows to change the SALT SETTING val-
ues. Press SET/REGEN again to accept the new value.
4. Press the DOWN and advance to the UNIT CAPACITY menu option. Press SET/REGEN to
edit the UNIT CAPACITY. Press UP OR DOWN arrows to change the UNIT CAPACITY val-
ues. Press SET/REGEN again to accept the new value.
5. Press MENU to exit programming mode.
MODEL
VALVE SETTINGS (MINUTES)
MUNICIPAL WATER (HIGH EFFICIENCY) MUNICIPAL WATER (HIGH CAPACITY) PROBLEM WATER (HIGH CAPACITY)
BACKWASH
BRINE /
RINSE
RINSE BACKWASH
BRINE /
RINSE
RINSE BACKWASH
BRINE /
RINSE
RINSE
ECS-20 1 21 1 1 35 1 4 35 4
ECS-24 1 23 1 1 52 1 5 52 5
ECS-34 2 33 1 2 80 1 10 80 10
SALT
SETTING
UNIT
CAPACITY
SALT
SETTING
UNIT
CAPACITY
SALT
SETTING
UNIT
CAPACITY
ECS-20 1.5 7,300 3.0 12,000 5.0 14,000
ECS-24 2.1 11,800 3.7 18,000 7.0 19,600
ECS-34 2.4 13,400 5.3 20,500 8.0 22,400
ECS-39 3.0 15,400 6.0 25,700 10.0 30,000
MODEL
HIGH EFFICIENCY
HIGH CAPACITY
PROBLEM WATER