User`s manual
U.S. Robotics I-modem Command Reference
Appendix A: Alphabetic Command Summary • Page A-40
3 8 Enable V.23. Required for some British connections.
6 64 Disable the remote-access busy message.
7 128 Disable V.32terbo.
S38 0 Sets the duration, in seconds, before a forced hang-up and clearing of the
Transmit buffer when DTR drops during an ARQ call. This is provided to
allow time for a remote device to acknowledge receipt of all transmitted
data.
Default = 0: The I-modem immediately hangs up when DTR drops. If the I-
modem receives the ATH command, it ignores S38 and immediately hangs
up.
S41 0 Sets the number of allowable remote-access login attempts, thus enabling
or disabling remote access. The default setting of zero allows no remote
login attempts, thus disabling remote access. A value of 1 or greater
enables remote access. If the number of unsuccessful login attempts
exceeds the limit set by this register, the I-modem returns online and any
further login attempts during the remainder of that connection are refused.
S42 126 Stores the ASCII decimal code for the remote-access escape character.
The default character is a tilde (~).
S43 200 Sets the duration, in Þftieths of a second, of the guard time for the remote-
access (~~~~) sequence.
Table AÐ1. S-register
s: Their Functions and Default Settings
Register Default Function