User`s manual

U.S. Robotics I-modem Command Reference
Appendix A: Alphabetic Command Summary • Page A-34
3 8 On DTR signal, autodial the number stored in
NVRAM
at position 0 (external I-modem only).
4 16 At power-on/reset, autodial number stored in
NVRAM at position 0.
5 32 Disable HST (used for testing V.32terbo in Dual Stan-
dard I-modems).
6 64 Disable MNP Level 3 (used for testing Level 2).
7 128 Hardware reset (works like powering off and then
on).
S14 1 Bit-mapped register. (See Chapter 1, Using the A
T Command Set, for
instructions about how to set bit-mapped registers.)
Bit Value Result
0 1 Disconnect on escape code.
1 2 Send result codes only when originating a call.
S15 0 Bit-mapped register. (See Chapter 1, Using the A
T Command Set, for
instructions about how to set bit-mapped registers.)
Table AÐ1. S-registers: Their Functions and Default Settings
Register Default Function