User`s manual

U.S. Robotics I-modem Command Reference
Testing • Page 14-11
tal loopback mode. If you are using an external I-modem, the MR status light ßashes
during this operation.
5. Type a short message. It will be looped back to your I-modem by the remote device and
to your screen for veriÞcation. (The remote user will not see your data.)
6. Send the escape code, +++, and then ATS16=0 to end the test.
If you issue an invalid command, the I-modem sends an ERROR message. If you set
Register S18, the I-modem automatically ends the test when the test timeout is reached.
If you wish to resume data transmission with the remote device, add the O command
after the ATS16=0 string to return online. If you do this, bear in mind that error control
is disabled. Because error control is negotiated during the connection sequence, its sta-
tus cannot be changed until the I-modem is back on hook and in Command mode
.
7. Send AT&M4, unless you used a reset command (ATZ or ATZ!).
Testing Using a Built-in Test Pattern (S16=4)
Starting Testing That Uses the Test Pattern
The test pattern is available at all speeds. At 300 bps, the I-modem's serial port rate must
be Þxed (&B1) and the link rate Þxed at 300 bps (&N1). At rates over 9600 bps, just set
the I-modem for a Þxed serial port rate (&B1).