Querying • Page 12-17
Disconnect Reasons for Dial Security
I7 Display the product conÞguration. If you have a problem and call U.S.
Robotics' Technical Support staff, you may be asked to read this screen.
Table 12-3. Dial Security Disconnect Reasons
Disconnect
Reason Explanation
Mode
Incompatible
The I-modem hung up because both devices were not set to the same error-con-
trol setting.
No Prompting
in Non-ARQ
Prompting was enabled, but the I-modem hung up because the originating
device was set for error control, and the answering device was set for non-error
control. The answering device cannot prompt when it is set for non-error control.
No Prompting
in Sync
(External
I-modems only)
The originating device did not send an Autopass password, and the answering
device cannot prompt for a password in any synchronous
mode.
Non-ARQ Mode The I-modem hung up because the originating device was set for error control
and the answering device was set for non-error control.
Prompting Not
Enabled
The I-modem hung up because the originating device did not send an Autopass
password, and prompting wasn't enabled.