58 56K Message Modem
S-Registers
To change a setting, use the ATSr=n command, where r is
the register and n is a decimal value from 0 − 255 (unless
otherwise indicated).
Register Default Function
S0 0 Sets the number of rings on which to answer in Auto
Answer Mode. When set to 0, Auto Answer is
disabled.
S1 0 Counts and stores the number of rings from an
incoming call. (S0 must be greater than 0.)
S2 43 Stores the ASCII decimal code for the escape code
character. Default character is +. A value of 128 –
255 disables the escape code.
S3 13 Stores the ASCII code for the Carriage Return
character. Valid range is 0 – 127.
S4 10 Stores the ASCII decimal code for the Line Feed
character. Valid range is 0 – 127.
S5 8 Stores the ASCII decimal code for the Backspace
character. A value of 128−255 disables the
Backspace key’s delete function.
S6 2 Sets the number of seconds the modem waits
before dialling. If Xn is set to X2 or X4, this is the
time-out length if there isn't a dial tone.
S7 60 Sets the number of seconds the modem waits for a
carrier. May be set for much longer duration if, for
example, the modem is originating an international
connection.