Product data
USRobotics
Command Reference
Data Command Set - 53
+ES=3,,2 Enable V.42 with Detection Phase originator, allow LAPM, MNP,
or Normal Mode connection answer. Disable Synchronous
Access Mode originator and answerer.
Reporting Current or Selected Values
Command: +ES?
Response: +ES: <orig_rqst>,<orig_fbk>,<ans_fbk>
Example: +ES: 3,0,2 For default settings.
+ES: 6,0,8 For V.80 Synchronous Access Mode originator and
answerer.
Reporting Supported Range of Parameter Values
Command: +ES=?
Response: +ES: (<orig_rqst> range),( <orig_fbk> range), (<ans_fbk> range)
Example: +ES: (0-4,6),(0-4),(0-6,8)
+EB - Break Handling in Error Control Operation
This extended-format compound parameter controls the break handling in V.42
operation. It accepts three numeric subparameters:
Syntax
+EB=[<break_selection>[,<timed>[,<default_length>]]]
Defined Values
<break_selection>
Decimal number 0 specifying that break is to be ignored, i.e., not
signaled to remote DCE.
<timed> Decimal number 0 specifying that any transmitted V.42 LSIGNAL
will not indicate break signal length
<default_length>
Decimal number 0 specifying that break is not delivered to the
DTE.
Reporting Current or Selected Values
Command: +EB?
Response: +EB: <break_selection>,<timed>,<default_length><CR>
Example: +EB: 0,0,0 For default settings.