Owner's Manual

Part Number 1955202 rev 5 4/15 7
DIMENSIONS AND SPECIFICATIONS, MODEL SGM
“D”
TOP VIEW
38"
[965mm]
25-3/8"
[645mm]
54-9/16"
[1386mm]
3/4" N.P.T.
GAS INLET
3/4" REAR
GAS INLET
1" REAR
GAS INLET
7-3/4"
[197mm]
2"
[51mm]
3/4"
[19mm]
(includes
motor)
FLUE: 2-3/8" x 5"
[60mm x 127mm]
38-1/4"
[972mm]
11-1/2"
[292mm]
17-3/4"
[451mm]
1-1/4"
[32mm]
32-1/8"
[816mm]
34"
[864mm]
SINGLE DECK
FRONT VIEW
6-1/4"
[159mm]
DOUBLE DECK
FRONT VIEW
32-1/8"
[816mm]
32-1/8"
[816mm]
1-1
/4"
[32mm]
32-1/8"
[816mm]
32-1/8"
[816mm]
14-3/4"
[375mm]
35-7/16"
[900mm]
Model
Int. Dimensions :In (mm) Ext. Dimensions: In (mm) Ship Wt Ship Dim.
W H D W H D Lbs/kg Cubic Ft.
SGM-100S1 29 (736) 24 (610) 24 (610) 38 (965) 57-1/2 (1461) 39-1/4(997) 510/232 42
SGM-100D1 29 (736) 24 (610) 28 (711) 38 (965) 57-1/2 (1461) 43-1/4(1099) 510/232 42
SGM-200S1 29(736) 24(610) 24(610) 38(965) 70-1/2 (1791) 39-1/4(997) 1024/464 84
SGM-200D1 29(736) 24(610) 28 (711) 38(965) 70-1/2 (1791) 43-1/4(1099) 1024/464 84
Models
Input Ratings, Natural & Propane Operating Pressure * Electrical Speci cations
BTU/hr
kW
Equiv.
Gas Inlet Natural Propane 120V/1Ph. 240V/1Ph.
Single Deck 60,000 17. 6 (1 )@ 3/4" NPT
4.5" WC
(11 mbar)
10" WC
(25 mbar)
(1)@9.8A (1)@ 5.2A
Double Deck 120,000 35.2 (1 )@1" NPT (2)@9.8A (2)@ 5.2A
*Maximum Pressure 13.8" WC @ 70°F (21°C).
Many local codes exist and it is the responsibility of the owner and installer to comply with those codes.
These appliances are intended for commercial use by professionally trained personnel.
Notes:
1. Standard electrical speci cations include motor requirements.
2. (120V units) 115V 3/4 HP, 2-speed motor; 1140 and 1725 rpm 60Hz
3. (240V units) 200-240V, 3/4 HP, 2-speed motor; 1140 and 1725 rpm, 60Hz
4. A 6 ft. line cord is provided for each 120V deck with a (NEMA #5-15P) plug.
5. U.S. Range recommends a separate 15 AMP circuit for each 120V unit.
(Models Discontinued, Manufactured Up To June 2012)