Users Manual
EM500-UDL User Guide
24
Prevention
Set Value
Setting value=| A - B | / C * 100%.
( A=current measured value; B=previous measured val
ue; C=maximum range)
If the current measured value exceeds the set value
after calculation by the previous formula, it is abnorm
al and device will measure again.
Null
6.2.3 Threshold
Location:
Ursalink ToolBox(PC): Device Settings → Threshold Settings
Ursalink ToolBox(APP): Device → Settings → Threshold Settings
Threshold Settings
Item Description Default
Distance/Level
Enable: The device will send the latest distance/level
value to network server if it
goes above/below
distance/level thresholds.
Disabled
Over Enter the maximum distance/level threshold. Null
Below Enter the minimum distance/level threshold. Null
Example: Set the "Lockout Time" for 10min, "Duration" for 5min.
The device will report the detected value immediately when the value reachs the threshold and
last for 5mins. After that, the device will check the deteced value every 10 mins, and report the
value again if it reaches the threshold and last for 5mins.
7.Sensor Management via Ursalink Cloud
Ursalink cloud is a comprehensive platform that provides multiple services including device
remote management and data visualization with the easiest operation procedures.
7.1 Ursalink Cloud Registration
Register and log in Ursalink Cloud.
Ursalink Cloud URL: https://cloud.ursalink.com/login.html