Instruction Manual

05
TECHNICAL SPECIFICATIONS
Warning: press “RESET” button only when you actually exchange the bag or you will lose the seconds counting.
Weight without bag
Max fog emission in a single shot
Total fog emission capacity with full bag
Fog bag capacity
Working time without mains power
Average power consumption during heating
Heating time
Average power consumption range
Maximum current consumption at 14.1 V
Batteries type suggested
Cover tamper
RTC real time clock
LAN & WIFI board support
8 Kg
200 m
3
1275 m
3
750 ml
over 1 hour
170 W + 10
about 1,5 hour
37- 41 W
1.2 A
Pb 2 Ah 12V
microswitch
Yes
Yes
9 Kg
300 m
3
1350 m
3
750 ml
over 1 hour
170 W + 10
about 1 hour
37- 41 W
1.4 A
Pb 2 Ah 12V
microswitch
Yes
Yes
10 Kg
400 m
3
1200 m
3
750 ml
over 1 hour
280 W + 10
about 1 hour
42- 47 W
2.3 A
Pb 2 Ah 12V
microswitch
Yes
Yes
10 Kg
500 m
3
1500 m
3
750 ml
over 1 hour
280 W + 10
about 2 hours
42- 47 W
2.5 A
Pb 2 Ah 12V
microswitch
Yes
Yes
11 Kg
800 m
3
2400 m
3
1000 ml
over 1 hour
280 W + 10
about 2 hours
48- 53 W
2.8 A
Pb 2 Ah 12V
microswitch
Yes
Yes
MODULAR
2 PLUS
MODULAR
3 PLUS
MODULAR
4 PLUS
MODULAR
5 PLUS
MODULAR
8 PLUS
- Do not disconnect the units from its power immediately after the shoting fog
- Change the battery every two years
- Change the bag as soon as the “empty” signal appears
- The generator must have the side holes free for air ventilation
WARNING:
5