Instruction Manual

Small fog flow coming out
from nozzle
Too low battery level or
exaust
Bag in Reserve or
Empty
No Mains power
Disturbance / interference
or potential differences
between devices
This condition is normal and can happen on first
installation, it will completely disappear in a while
when the unit will become completely hot.
Replace Battery
Error on thermocouple, resistor.
Please refer to technical service
Check mains power or F4 fuse
In the evenience of high noise on mains power
(lightings) an error while reading thermocouple
values can occur. Execute a complete Power
Down (mains and battery) to recover unit.
If even recovery fails the unit may be faulty
In very large installations or with more than one
fog units connected to the same alarm panel,
a mains power difference can occur, in that
evenience the units have to be decoupled
Replace fluid Bag
Switch off the unit and verify the screw on TC2
connector
Error in the thermal loop
Heater Temperature too high
or thermocouple error
RED Led ON (Fault)
All products are 100%
tested before shipping and
a small ammount of liquid
could be still in the
warming unit
Switch off the unit and clean air holes Poor ventilation
RED Led ON (Error)
DEFECT FOUND POSSIBLE CAUSE POSSIBLE SOLUTION
15
FAULT-DEFECTS POSSIBLE SOLUTION
16