Instruction Manual

14
MAINTENANCE
UR FOG fogging systems don’t need special maintance, nevertheless is suggested a periodical check to the following parts
by skilled operators:
1) Verify battery and power supply status.
2) Verify screws are firmly closed.
3) Verify the output nozzle is not damaged and without anyting inside.
4) Verify pneumatic circuit.
5) Verify once a year liquid pump.
BATTERY AND PSU VOLTAGES
Verify that the output of the power supply without any load (battery unplugged ) is 14,1 V on the PSU and 13,8 V
on FASTON battery connectors.If a different value is noticed , set the trimmer on power supply.
Verify battery status (integrity check, no overheating); is suggested to replace the battery on 2 years base due to the
heavy load during shots without mains power.
SCREWS
Verify that all fixing screws are correctly setted and eventually rescrew them.
OUTPUT NOZZLE
Verify that ouput nozzle is not damaged and that there is nothing inside blocking the fog ejection flow.
YEARLY PUMP FUNCTIONALITY TEST
The test is done executing a trial shot on the unit.
To avoid creating too much fog during the test is suggested to stop the flow after a few seconds dearming
the unit under test.
The fog flow will immediatly stop.
15