Instruction Manual
11
CONNECTION EXAMPLES
Modular Plus family fogging systems are designed to be simply connected to any existing Alarm Panel available on the
market.
In compliance to the existing rules and for security purpose the activation of the fog emission should be as a result of a
“double confirmation” input.The meaning of the “ARM” signal is to be intended as a 1st confirmation.
If a TRIG command or a PIR validation input (if active) is received by the unit in “ARM” status (Blue led on), the unit will
generate fog for the time previously programmed and stored in the unit via the time setting procedure.
The unit is able to handle both activation method commonly used by fogging systems.
A) Siren emulation:
1) ARMING: When the intruder alarm system is armed (local monitoring with sensors and active zones) a latched output
must be sent to the unit (12v DC + to the ARMP PIN and 12v DC - to the ARMN PIN). The Blue LED on the unit lights up
to signal the armed status.
2) SHOOTING: In the case of an alarm activation the intruder alarm system for an event signaled by an area or sensor,
the alarm panel must send a impulse signal (duration >500ms) to the unit (12v DC + to the PIN TRGP and 12v DC - to
the PIN TRGN). The device activates instantaneously and emits fog for the preset time.
B) Relay activation:
1) ARMING: Define on the intruder alarm panel an area dedicated to the arming of the fog device.
The relay in this area (NO) will have to close when the alarm system is activated.
2) SHOOTING: Define on the intruder alarm panel an area dedicated to allow the emission of fog by the unit.
The relay in this area (NO) will have to close when the intruder alarm system is activated in by an event detected by
an area or sensor.
Please note that if the ARMED signal is removed during the shooting, the units immediatly stops fog emission.
Optional shooting methods.
Other activation methods are available on the Modular Plus series, some of which are dependant on optional devices.
This provides the installer with a range of common wiring options to suit all applications.
A) Additional TRIG button
The input IN0P/IN0N is an optional trig command device that can be added to command the fog emission.It acts exactly as
TRGP/TRGN input and follows the same rules.
B) Panic/HUA Antirobbery TRIG button
The input IN1P/IN1N is an optional trig command that enables the device to create fog EVEN WITHOUT BEING ARMED.
This option must only be set up if the end user is trained around its operational capabilities and on how and when to use
this option.To prevent accidental activation it this recommended that a dual push HUA button is installed.This function must
be activated by the installer only , that take the responsability to train users. To activate Panic HUA functions, move SW5 to
the ON position, and then reboot the unit.
C) Cloud Monitoring/Activation by remote
The Modular Plus Series can be equipped with the URF0g ActiveCloud LAN board , that allows Ethernet (RJ45 or WiFi)
connectivity to full monitor , diagnostic and be interactive with the unit by remote.Please refer to you local URFog dealer for
more details
D) PIR INPUT
A local PIR sensor can be installed near the device and directly connect to the Modular Plus board to activate the trig only if
presence is detected in the shooting area.This function is activated by closing the W1 (PIR INPUT ACTIVE) and works in AND
with the normal TRIG input received from the alarm panel.By closing ALSO W2 Jumper the PIR INPUT confirmation will let
the PIR work as standalone activation device.Turn off and back on the unit after Jumper setting.
12