Installation manual
6 Underfloor Heating
3. Installation
Installation steps
Uponor recommends that you follow the steps described
below to guarantee the best possible installation:
3.1 Preparation before installation
Before beginning the installation:
• Verify the contents of the package with the list shown in
Section 2 to make sure you have all the necessary
products;
• Check whether a floor sensor has been mounted;
• Study the wiring diagram in the fold-out or inside the
controller cover.
• A controller should be installed close to each manifold;
• A power outlet is required for the connection of the
controller to the mains;
• The mounting locations for the Uponor Control System
must be protected from running and dripping water;
• Put one thermostat for every room fitted with a heating
floor (one thermostat can control several loops of the
heating floor).
3.2 Installation of the components
Mounting the controller (6 or 12-channel)
• Check that the cover of the controller can easily be
removed.
• Check that the connectors and switches are easily
accessible.
Description
3.1
Preparation before installation
3.2
Installation of the components
(controller and thermostats)
3.3
Connections
(thermostats and actuators to controller)
3.4
Room thermostats
3.5
Floor sensor thermostats
4
Finishing the installation
STOP
The controller has to be mounted horizontally.
There is a risk for overheating if the controller is
mounted vertically or on a horizontal surface.
Drill the wall (Ø6 mm)
Press the anchor into the hole (if concrete wall)
Attach the controller to the wall with screws
1
2
3
INSTALLATION_MANUAL_R3-04A.mif Page 6 Mercredi, 14. mars 2007 11:34 11