Installation and Operation Manual
Table Of Contents
- Uponor Smatrix Wave PULSE
- Table of contents
- 1 Copyright and disclaimer
- 2 Preface
- 3 Uponor Smatrix Wave PULSE system description
- 3.1 System overview
- 3.2 Example of a system
- 3.3 Uponor Smatrix Wave PULSE components
- 3.4 Accessories
- 3.5 Functions
- 4 Install Uponor Smatrix Wave PULSE
- 5 Install Uponor Smatrix Wave PULSE room controller
- 5.1 Placement of room controller
- 5.2 Connect optional slave module
- 5.3 Attach room controller to the wall
- 5.4 Install room controller antenna
- 5.5 Install communication module
- 5.6 Connect actuators to room controller
- 5.7 Connect electrical underfloor heating
- 5.8 Connect input to room controller GPI
- 5.9 Connect output to room controller relays
- 5.10 Connect room controller to AC power
- 5.11 Test actuators
- 6 Install Uponor Smatrix Wave room thermostat
- 6.1 Uponor Smatrix Wave T-161
- 6.2 Uponor Smatrix Wave T-163
- 6.6 Uponor Smatrix Wave T-169
- 9 Install Uponor Smatrix Wave relay module
- 9.1 Placement of relay module
- 9.2 Attach relay module to the wall
- 9.3 Connect output to relay module
- 9.4 Register relay module to room controller
- 9.5 Use relay module to connect fan coils
- 9.6 Use relay module for time delayed two stage additional cooling (requires communication module)
- 10 Install another Uponor Smatrix room controller in the system
- 11 Finishing installation
- 12 Operate Uponor Smatrix Wave PULSE room controller
- 12.1 Principle of operation
- 12.2 Normal operation without optional scheduling programs
- 12.3 Operation with scheduling programs
- 12.4 Run mode
- 12.5 Room controller LEDs
- 12.6 Reset the controller
- 12.7 Unregister room controller channels
- 13 Operate Uponor Smatrix PULSE communication module
- 14 Operate Uponor Smatrix Wave thermostats
- 16 Maintenance
- 17 Troubleshooting
- 17.1 General
- Fluctuating floor temperature
- The room is too cold (or too warm in cooling mode)
- Thermostat setpoint is too low
- The temperature displayed on the thermostat changes after the thermostat is moved
- Installation report and room controller/channel numbering on the thermostat label doesn't match
- Installation report and room controller/channel numbering on the thermostatic head label doesn't match
- White indicator cannot be seen in window of an actuator
- Setpoint temperature displayed in the room information menu is lower than the temperature set on the thermostat
- ECO mode
- The room is too warm (or too cold in cooling mode)
- The floor is cold
- All rooms are cold (or warm in cooling mode)
- Disturbing noise from the pump at the same time every week
- No communication
- Communication failure between the room controllers
- 17.2 Troubleshooting after installation
- 17.3 Digital thermostat alarms/problems
- 17.4 Analogue thermostat alarms/problems
- 17.5 Thermostatic head alarms/problems
- The text “bAt” is shown in the display
- The text “POS” is shown in the display
- The display is off
- Radio transmission icon is displayed but the signals are received only when the thermostatic head is close to the antenna
- No radio transmission icon is displayed on thermostatic head screen when buttons are pressed
- 17.6 Communication module alarms/problems
- Alarms shown in Uponor Smatrix PULSE app
- The communication module has lost communication with Uponor cloud services
- The communication module has re-established communication with Uponor cloud services
- Software update failed
- Thermostatic head valve position error
- Floor temperature limit reached
- Faulty temperature sensor
- Faulty external temperature sensor
- Faulty relative humidity sensor
- Faulty Comfort/ECO switch
- Relative humidity sensor limit
- Faulty outdoor temperature sensor
- Faulty heating/cooling supply sensor
- External heating/cooling switch lost
- General systems alarm
- High supply temperature
- Low supply temperature
- Thermostat tamper alarm
- Low average temperature
- Relay module lost
- The communication module does not start
- Bad Wi-Fi connection
- Alarms shown in Uponor Smatrix PULSE app
- 17.7 Room controller alarms/problems
- 17.8 Contact the installer
- 17.9 Installer instructions
- 17.1 General
- 18 Technical data
Components of the thermostat:
The illustration below shows the thermostat and its components.
A
B C D E
CD0000031
Item Description
A Uponor Smatrix Wave T-161
B Wall bracket
C Adhesive tape
D Battery (CR2032 3V)
E Mounting hardware
Uponor Smatrix Wave PULSE
|
Installation and operation manual
|
9
Uponor Smatrix Wave T-169 digital thermostat
The thermostat shows the ambient, set temperature, or relative
humidity on the display. Temperature settings are adjusted using /
buttons on the side of the thermostat.
Main characteristics:
• Power saving e-paper display (updates every 10 minutes).
• Displays Celsius or Fahrenheit.
• Operative sensor for increased comfort.
• Calibration of displayed room temperature.
• Heating/cooling demand as well as low battery indication on
display.
• Displays Uponor logo and software version during power up
sequence.
• Setpoint range is 5 – 35 °C (maximum and minimum setting may
be limited by other system settings).
• Room temperature regulation with use of optional external
temperature sensors.
• Displays optional temperature sensor values if sensors are
connected and relevant room temperature regulation is
activated.
• Switch between Comfort and ECO mode with scheduling
(requires Uponor Smatrix PULSE app).
• Adjust ECO setback value.
• Relative humidity limit alarm indicated in display (requires
communication module).
• Invert display color.
• Can be placed up to 30 meters away from the room controller.
Components of the thermostat:
The illustration below shows the thermostat and its components.
A
B C D E
CD0000027
Item Description
A Uponor Smatrix Wave T-169
B Wall bracket
C Adhesive tape
D Battery (CR2032 3V)
E Mounting material
Expansion module
The Uponor Smatrix Wave room controller can be expanded with six
extra channels and actuator outputs using a Slave module.
Uponor Smatrix Wave M-262
Note
Only one slave module extension is supported per room
controller
.
Main characteristics:
• Easy plug in installation on existing room controller, no additional
wiring needed.
• Register up to six extra thermostats to the system.
• Connect up to six extra actuators (24 V).
• Electronic control of actuators.
• Valve exercise.
Components of the slave module
The illustration below shows the slave module and its components.
A B C
CD0000033
Item Description
A Uponor Smatrix Wave M-262
B DIN rail
C Mounting material
Relay module
The relay module adds two extra output relays to the system.
Uponor Smatrix Wave M-161
Main characteristics:
• Potential free contacts (24 VAC, 5 A).
• Requires an Uponor Smatrix Wave room controller.
• Pump control and heating/cooling output function.
• Pump and dehumidifier control function (requires communication
module and Uponor Smatrix PULSE app).
• Boiler and chiller control function (requires communication
module and Uponor Smatrix PULSE app).
• Comfort/ECO and ventilation control function (requires
communication module and Uponor Smatrix PULSE app).
• Fan coil control (requires communication module and Uponor
Smatrix PULSE app for the fan coil to be linked to a room
channel).
• Optional two stage cooling function (requires activation on the
relay module, and the communication module).
See Use relay module for time delayed two stage additional
cooling (requires communication module), Page 68 for more
information.
• Can be placed up to 30 meters away from the room controller.