Installation and Operation Manual
Table Of Contents
- Uponor Smatrix Wave PULSE
- Table of contents
- 1 Copyright and disclaimer
- 2 Preface
- 3 Uponor Smatrix Wave PULSE system description
- 3.1 System overview
- 3.2 Example of a system
- 3.3 Uponor Smatrix Wave PULSE components
- 3.4 Accessories
- 3.5 Functions
- 4 Install Uponor Smatrix Wave PULSE
- 5 Install Uponor Smatrix Wave PULSE room controller
- 5.1 Placement of room controller
- 5.2 Connect optional slave module
- 5.3 Attach room controller to the wall
- 5.4 Install room controller antenna
- 5.5 Install communication module
- 5.6 Connect actuators to room controller
- 5.7 Connect electrical underfloor heating
- 5.8 Connect input to room controller GPI
- 5.9 Connect output to room controller relays
- 5.10 Connect room controller to AC power
- 5.11 Test actuators
- 6 Install Uponor Smatrix Wave room thermostat
- 6.1 Uponor Smatrix Wave T-161
- 6.2 Uponor Smatrix Wave T-163
- 6.6 Uponor Smatrix Wave T-169
- 9 Install Uponor Smatrix Wave relay module
- 9.1 Placement of relay module
- 9.2 Attach relay module to the wall
- 9.3 Connect output to relay module
- 9.4 Register relay module to room controller
- 9.5 Use relay module to connect fan coils
- 9.6 Use relay module for time delayed two stage additional cooling (requires communication module)
- 10 Install another Uponor Smatrix room controller in the system
- 11 Finishing installation
- 12 Operate Uponor Smatrix Wave PULSE room controller
- 12.1 Principle of operation
- 12.2 Normal operation without optional scheduling programs
- 12.3 Operation with scheduling programs
- 12.4 Run mode
- 12.5 Room controller LEDs
- 12.6 Reset the controller
- 12.7 Unregister room controller channels
- 13 Operate Uponor Smatrix PULSE communication module
- 14 Operate Uponor Smatrix Wave thermostats
- 16 Maintenance
- 17 Troubleshooting
- 17.1 General
- Fluctuating floor temperature
- The room is too cold (or too warm in cooling mode)
- Thermostat setpoint is too low
- The temperature displayed on the thermostat changes after the thermostat is moved
- Installation report and room controller/channel numbering on the thermostat label doesn't match
- Installation report and room controller/channel numbering on the thermostatic head label doesn't match
- White indicator cannot be seen in window of an actuator
- Setpoint temperature displayed in the room information menu is lower than the temperature set on the thermostat
- ECO mode
- The room is too warm (or too cold in cooling mode)
- The floor is cold
- All rooms are cold (or warm in cooling mode)
- Disturbing noise from the pump at the same time every week
- No communication
- Communication failure between the room controllers
- 17.2 Troubleshooting after installation
- 17.3 Digital thermostat alarms/problems
- 17.4 Analogue thermostat alarms/problems
- 17.5 Thermostatic head alarms/problems
- The text “bAt” is shown in the display
- The text “POS” is shown in the display
- The display is off
- Radio transmission icon is displayed but the signals are received only when the thermostatic head is close to the antenna
- No radio transmission icon is displayed on thermostatic head screen when buttons are pressed
- 17.6 Communication module alarms/problems
- Alarms shown in Uponor Smatrix PULSE app
- The communication module has lost communication with Uponor cloud services
- The communication module has re-established communication with Uponor cloud services
- Software update failed
- Thermostatic head valve position error
- Floor temperature limit reached
- Faulty temperature sensor
- Faulty external temperature sensor
- Faulty relative humidity sensor
- Faulty Comfort/ECO switch
- Relative humidity sensor limit
- Faulty outdoor temperature sensor
- Faulty heating/cooling supply sensor
- External heating/cooling switch lost
- General systems alarm
- High supply temperature
- Low supply temperature
- Thermostat tamper alarm
- Low average temperature
- Relay module lost
- The communication module does not start
- Bad Wi-Fi connection
- Alarms shown in Uponor Smatrix PULSE app
- 17.7 Room controller alarms/problems
- 17.8 Contact the installer
- 17.9 Installer instructions
- 17.1 General
- 18 Technical data
1 Copyright and disclaimer
Uponor has prepared this installation and operation manual and all
the content included solely for information purposes. The contents of
the manual (including graphics, logos, icons, text, and images) are
copyrighted and protected by worldwide copyright laws and treaty
provisions. You agree to comply with all copyright laws worldwide in
your use of the manual. Modification or use of any of the contents of
the manual for any other purpose is a violation of Uponor’s copyright,
trademark and other proprietary rights.
The presumption for the manual is that the safety measures have
been fully complied with and, further, that Uponor Smatrix control
system, including any components that are part of such system,
covered by the manual:
• is selected, planned and installed and put into operation by a
licensed and competent installer in compliance with current (at
the time of installation) installation instructions provided by
Uponor as well as in compliance with all applicable building and
plumbing codes and other requirements and guidelines;
• has not been (temporarily or continuously) exposed to
temperatures, pressure and/or voltages that exceed the limits
printed on the products or stated in any instructions supplied by
Uponor;
• remain in its originally installed location and is not repaired,
replaced or interfered with, without prior written consent of
Uponor;
• is connected to potable water supplies or compatible plumbing,
heating and/or cooling products approved or specified by
Uponor;
• is not connected to or used with non-Uponor products, parts or
components except for those approved or specified by Uponor;
and
• does not show evidence of tampering, mishandling, insufficient
maintenance, improper storage, neglect or accidental damage
before installation and being put into operation.
While Uponor has made efforts to ensure that the manual is accurate,
Uponor does not guarantee or warrant the accuracy of the
information contained herein. Uponor reserves the right to modify the
specifications and features described herein, or discontinue
manufacture of the Uponor Smatrix products described at any time
without prior notice or obligation. The manual is provided “as is”
without warranties of any kind, either expressed or implied. The
information should be independently verified before using it in any
manner.
To the fullest extent permissible, Uponor disclaims all
warranties, expressed or implied, including, but not limited to,
the implied warranties of merchantability, fitness for particular
purpose and non-infringement.
This disclaimer applies to, but is not limited to, the accuracy, reliability
or correctness of the manual.
Under no circumstances shall Uponor be liable for any indirect,
special, incidental or consequential damages or loss that result
from the use of or the inability to use the materials or
information in the manual, or any claim attributable to errors,
omission or other inaccuracies in the manual, even if Uponor
has been advised of the possibility of such damages.
This disclaimer and any provisions in the manual do not limit
any statutory rights of consumers.
4
|
Uponor Smatrix Wave PULSE
|
Installation and operation manual
Compliance
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions:
(1) 1) This device may not cause harmful interference,
and
(2) 2) This device must accept any interference
received, including interference that may cause
undesired operation.
Note: The grantee is not responsible for any
changes or modifications not expressly approved by
the party responsible for compliance.
Such
modifications could void the user’s authority to
operate the equipment.:
FCC ID: V9MSM4NA0 and V9MSM4NA1
IC: 7664A-SM4NA0 and 7664A-SM4NA1
This device contains licence-exempt transmitter(s)/
receiver(s) that comply with Innovation, Science and
Economic Development Canada’s licence-exempt
RSS(s). Operation
is subject to the following two
conditions:
(1) This device may not cause interference.
(2) This device must accept any interference,
including interference that may cause undesired
operation of the device.
L’émetteur/récepteur exempt de licence contenu
dans le présent appareil est conforme aux CNR
d’Innovation, Sciences
et Développement
économique Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux
deux conditions suivantes :
1) L’appareil ne doit pas produire de
brouillage;
2) L’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.