Installation and Operation Manual
Table Of Contents
- Uponor Smatrix Wave PULSE
- Table of contents
- 1 Copyright and disclaimer
- 2 Preface
- 3 Uponor Smatrix Wave PULSE system description
- 3.1 System overview
- 3.2 Example of a system
- 3.3 Uponor Smatrix Wave PULSE components
- 3.4 Accessories
- 3.5 Functions
- 4 Install Uponor Smatrix Wave PULSE
- 5 Install Uponor Smatrix Wave PULSE room controller
- 5.1 Placement of room controller
- 5.2 Connect optional slave module
- 5.3 Attach room controller to the wall
- 5.4 Install room controller antenna
- 5.5 Install communication module
- 5.6 Connect actuators to room controller
- 5.7 Connect electrical underfloor heating
- 5.8 Connect input to room controller GPI
- 5.9 Connect output to room controller relays
- 5.10 Connect room controller to AC power
- 5.11 Test actuators
- 6 Install Uponor Smatrix Wave room thermostat
- 6.1 Uponor Smatrix Wave T-161
- 6.2 Uponor Smatrix Wave T-163
- 6.6 Uponor Smatrix Wave T-169
- 9 Install Uponor Smatrix Wave relay module
- 9.1 Placement of relay module
- 9.2 Attach relay module to the wall
- 9.3 Connect output to relay module
- 9.4 Register relay module to room controller
- 9.5 Use relay module to connect fan coils
- 9.6 Use relay module for time delayed two stage additional cooling (requires communication module)
- 10 Install another Uponor Smatrix room controller in the system
- 11 Finishing installation
- 12 Operate Uponor Smatrix Wave PULSE room controller
- 12.1 Principle of operation
- 12.2 Normal operation without optional scheduling programs
- 12.3 Operation with scheduling programs
- 12.4 Run mode
- 12.5 Room controller LEDs
- 12.6 Reset the controller
- 12.7 Unregister room controller channels
- 13 Operate Uponor Smatrix PULSE communication module
- 14 Operate Uponor Smatrix Wave thermostats
- 16 Maintenance
- 17 Troubleshooting
- 17.1 General
- Fluctuating floor temperature
- The room is too cold (or too warm in cooling mode)
- Thermostat setpoint is too low
- The temperature displayed on the thermostat changes after the thermostat is moved
- Installation report and room controller/channel numbering on the thermostat label doesn't match
- Installation report and room controller/channel numbering on the thermostatic head label doesn't match
- White indicator cannot be seen in window of an actuator
- Setpoint temperature displayed in the room information menu is lower than the temperature set on the thermostat
- ECO mode
- The room is too warm (or too cold in cooling mode)
- The floor is cold
- All rooms are cold (or warm in cooling mode)
- Disturbing noise from the pump at the same time every week
- No communication
- Communication failure between the room controllers
- 17.2 Troubleshooting after installation
- 17.3 Digital thermostat alarms/problems
- 17.4 Analogue thermostat alarms/problems
- 17.5 Thermostatic head alarms/problems
- The text “bAt” is shown in the display
- The text “POS” is shown in the display
- The display is off
- Radio transmission icon is displayed but the signals are received only when the thermostatic head is close to the antenna
- No radio transmission icon is displayed on thermostatic head screen when buttons are pressed
- 17.6 Communication module alarms/problems
- Alarms shown in Uponor Smatrix PULSE app
- The communication module has lost communication with Uponor cloud services
- The communication module has re-established communication with Uponor cloud services
- Software update failed
- Thermostatic head valve position error
- Floor temperature limit reached
- Faulty temperature sensor
- Faulty external temperature sensor
- Faulty relative humidity sensor
- Faulty Comfort/ECO switch
- Relative humidity sensor limit
- Faulty outdoor temperature sensor
- Faulty heating/cooling supply sensor
- External heating/cooling switch lost
- General systems alarm
- High supply temperature
- Low supply temperature
- Thermostat tamper alarm
- Low average temperature
- Relay module lost
- The communication module does not start
- Bad Wi-Fi connection
- Alarms shown in Uponor Smatrix PULSE app
- 17.7 Room controller alarms/problems
- 17.8 Contact the installer
- 17.9 Installer instructions
- 17.1 General
- 18 Technical data
Components of the relay module
The illustration below shows the relay module and its components.
A B
CD0000034
Item Description
A Uponor Smatrix Wave M-161
B Mounting hardware
Uponor actuators
Uponor actuators are mounted on top of the manifold valves and is
operated using either on/off signals or pulse width modulation (PWM)
signals.
A B
CD0000035
A Actuator has closed the valve – empty indicator
B Actuator has opened the valve – white indicator
On/off control
When installing a system with on/off control, manual balancing of the
system is required.
As soon as the temperature measured at a thermostat is lower
(heating mode) or higher (cooling mode) than the setpoint
temperature, a demand to change the room temperature is created
and sent to the room controller
. The room controller will open the
actuators according to current operating mode and other settings.
Once the set temperature is reached, this information is sent and the
actuators are closed. The indicator on the actuator shows, with a
white bar, how much it is opened. If indicator (white) is fully shown it
is fully opened, no white bar shown means that the actuator is closed.
Time to open and close an actuator may take a couple of minutes.
PWM control
Note
Autobalancing can be used in combination with hydronic
balancing.
PWM control is used when the Autobalancing function is active.
When installing a system with PWM control, all balancing valves can
be fully opened, the system is balanced automatically.
See Autobalancing, Page 13, for more information.
3.4 Functions
Note
Setting up a system with a communication module
requires a mobile device (smart phone/tablet).
The Uponor Smatrix room controler is used to operate an underfloor
heating and/or cooling system in a house.
The thermostats registered to the room controller is used to control
the actuators mounted on top of the manifold(s).
As soon as the temperature measured at a thermostat is lower
(heating mode) or higher (cooling mode) than the setpoint
temperature, a demand to change the room temperature is created
and sent to the room controller. The room controller will operate the
actuators according to current control mode and settings. This will
manage the flow to the floor loops in the room and adjust the room
temperature. Once the set temperature is reached, this information is
sent to the room controller and the demand is met.
12
|
Uponor Smatrix Wave PULSE
|
Installation and operation manual