Installation and Operation Manual
15 Technical data
15.1 Technical data
Thermostat T-161 and T-169
IP IP20, class III (IP: degree of inaccessibility to active parts of the product
and degree of water)
Max. ambient RH (relative humidity) 85% at 20 °C
CE marking
ERP IV
Low voltage tests EN 60730-1* and EN 60730-2-9***
EMC (electromagnetic compatibility requirements) tests EN 60730-1 and EN 301-489-3
ERM (electromagnetic compatibility and radio spectrum matters) tests EN 300 220-3
Power supply 1 x CR2032 3V
Voltage 2.4 V to 3.6 V
Rated impulse voltage 0.33 kV, OVC I
Pollution degree 2
Software class A
Operating temperature 0 °C to +45 °C
Storage temperature -10 °C to +65 °C
Radio frequency 912 MHz
Transmitter duty cycle <1%
Connection terminals 0.25 mm² to 0.75 mm² solid, or 0.34 mm² to 0.5 mm² flexible with ferrules
Uponor Smatrix Wave PULSE
|
Installation and operation manual
|
76
Antenna
IP IP20, class III (IP: degree of inaccessibility to active parts of the product
and degree of water)
Max. ambient RH (relative humidity) 85% at 20 °C
CE marking
Power supply From room controller
Radio frequency 912 MHz
Transmitter duty cycle <1%
Receiver class 2
Communication module R-208
IP IP20, class III (IP: degree of inaccessibility to active parts of the product
and degree of water)
Max. ambient RH (relative humidity) 85% at 20 °C
CE marking
Low voltage tests EN 60730-1* and EN 60730-2-9***
EMC (electromagnetic compatibility requirements) tests EN 60730-1 and EN 301-489-3
ERM (electromagnetic compatibility and radio spectrum matters) tests EN 300 220-3
Power supply From room controller