Installation and Operation Manual

Register relay module to thermostat
SI0000092
Note
If no button on the thermostat is pressed for about
8 seconds, while in a submenu, the current values will be
saved and the software exits to the settings menu. About
about 60 seconds later, it exits to run mode.
Register the relay module to a thermostat (already registered to a
room controller in the system) using settings menu 09 on the
thermostat.
47 |
Uponor Smatrix Wave PULSE
|
Installation and operation manual
Register to a T-169 thermostat
1. ENTER RELAY MODULE REGISTRATION MODE
SI0000127
Press and hold the register button on the relay module until the LEDs
on the module start flashing slowly.
2. ENTER SETTINGS MENU
3 s
SI0000114
Press and hold the OK button for about 3 seconds. The settings icon
and menu numbers is displayed in the top right corner of the display
.
3.
LOCA
TE MENU 09
09
SI0000123
Use buttons or to change the numbers to 09. The text Int no is
displayed.
4. ENTER PARAMETER EDIT MODE
NO
09
SI0000124
Press OK to enter parameter edit mode (the parameter starts
flashing).
5. REGISTER THERMOSTAT TO RELAY MODULE
YES
09
SI0000155
Use buttons or to change Int no to Int CNF.
6. REGISTRATION
CNF
09
NO
09
SI0000125
The connection indicator is shown in the thermostat display to show
that the registration process begins.
The text Int YES is shown in the thermostat display and the LEDS on
the relay module start flashing fast again, to turn off a few seconds
later.
7. CONFIRM REGISTRATION
SI0000118
Press OK to confirm the parameter change.