Install Instructions

Professional Plumbing Installation Guide
23
More Than the Recommended
Number of Expansions are Needed to
Make a Connection
Ensure the head is hand-tightened to
the expander tool.
Examine the segment fingers for
damage.
Be sure to completely cycle the tool on
each expansion (i.e., close the manual
tool handle or release the trigger).
Cold-weather Expansions
Temperatures affect the time required
for the tubing and ring to shrink onto
the fitting. The colder the temperature,
the slower the contraction time.
Warming ProPEX fittings and ProPEX
Rings reduces contraction time. Put
fittings and rings in your pockets prior
to installation to keep them warm.
Make ProPEX connections at
temperatures above 5°F (-15°C).
Fewer expansions are necessary in
temperatures below 40ºF (4.4°C).
Expansion with Proper Rotation
Expansion without Proper Rotation