Install Instructions

Professional Plumbing Installation Guide
45
Section 7
Plumbing Inspector Checklist
This checklist serves as a guideline to the
local authority and may not include all
applicable requirements. Please review
guidelines for the codes and standards
in Section 1 of this installation guide
as well as the local code in your area for
additional guidelines and restrictions.
Note: If any conflict exists between the
information contained in this installation
guide and that of the local code, the local
code always takes precedence.
Tubing, Fittings and
Valves
Uponor AquaPEX tubing — ASTM F876,
ASTM F877, CSA B137.5, NSF-pw
ProPEX fittings — Manufactured and
listed to ASTM F1960 and CSA B137.5
Valves ASME A112.18.1 or CSA
B125.3, NSF 61
Uponor offers a full line of EP products,
including the EP Valveless and EP Flow-
through Valveless manifolds; the EP
Branch and EP Flow-through Multi-port
tees; and various elbows, couplings, end
caps, plugs and faucet adapters.
The Uponor ProPEX connection method
is compatible with all Uponor EP
products. For detailed information on
manifold placement and connections,
refer to the Engineered Plastic (EP)
Valved Manifolds Installation Guide.
Tubing Limitations
Do not expose Uponor AquaPEX White
tubing to direct sunlight for more
than 30 days; do not expose Uponor
AquaPEX Red or Blue tubing to direct
sunlight for more than 90 days.
Do not install Uponor AquaPEX
tubing within 6" of any gas appliance
vents, with the exception of double-
wall B-vents or plastic vents (with a
minimum clearance of 1").
Do not install Uponor AquaPEX tubing
within 12" of non I.C.-rated light
fixtures, unless you have protected the
PEX line with suitable insulation.
Joints and Connections
Square-cut all tubing ends and ensure
they are free of burrs and debris before
making a connection.
Ensure fittings and connections comply
with manufacturer recommendations.
Make transition joints with
manufacturer-approved fittings.
ProPEX Fittings
Seat the Uponor AquaPEX tubing and
ProPEX Ring fully against the shoulder
of the fitting. The maximum gap
should be no more than the thickness
of a credit card.
To correct an improper connection, cut
a minimum of 2" from the end of the
tubing and use a new ProPEX Ring.