Submittal Sheet
1
ProPEX
®
is a registered trademark of Uponor, Inc. ProPEX
™
is a trademark of Uponor Ltd.
2
Visit listing agency’s website for complete information;
3
For ½", ¾", 1", 1¼", 1½" and 2" tubing only;
4
For ¾" tubing and larger.
ProPEX
®
Ring
Submittal Information
Revision E: May 29, 2013
Project Information
Job Name:
Location:
Part No. Ordered:
Engineer:
Date Submitted:
Contractor:
Submitted By:
Manufacturer’s Representative:
Approved By:
Technical Data
Material:
Engel-method Crosslinked Polyethylene (PEX-a)
Density:
926 to 940 kg/m
3
Degree of crosslinking:
70% to 89%
Product Information and Application Use
Manufactured from PEX-a material, Uponor ProPEX
®
Rings are required to make
a proper ProPEX connection.
1
The ProPEX Ring with Stop includes a leading edge
chamfer and stop edge.
Description
Part Number
Length
I.D.
O.D.
Weight
ProPEX Ring, ⅜"
ProPEX Ring with Stop, ½"
ProPEX Ring with Stop, ⅝"
ProPEX Ring with Stop, ¾"
ProPEX Ring with Stop, 1"
ProPEX Ring with Stop, 1¼"
ProPEX Ring with Stop, 1½"
ProPEX Ring with Stop, 2"
Q4690302
Q4690512
Q4690625
Q4690756
Q4691000
Q4691250
Q4691500
Q4692000
0.54"
0.63"
0.79"
0.87"
1.10"
1.35"
1.61"
1.97"
0.49"
0.63"
0.75"
0.88"
1.13"
1.38"
1.63"
2.14"
0.74"
0.87"
1.00"
1.13"
1.42"
1.66"
1.91"
2.61"
0.005 lbs.
0.006 lbs.
0.008 lbs.
0.012 lbs.
0.020 lbs.
0.030 lbs.
0.040 lbs.
0.133 lbs.
Installation
Square cut the Uponor ProPEX tubing. Remove excess material. Slide the ProPEX Ring over the end of the tubing (maximum
1
/
16
" over-hang
for rings without stop). When using the ProPEX Ring with Stop, slide the ring on the tubing with the chamfered edge first until the end of the
tubing contacts the stop edge. Expand the tubing and ring. If using the ProPEX Manual Expander Tool, rotate the tool a quarter turn after
each expansion to prevent the formation of grooves. Remove the expansion tool and fully seat the tubing and ring against the shoulder of the
fitting. Make ProPEX connections at temperatures above 5°F/-15°C. For more information, refer to the AquaPEX
®
Professional Plumbing
Installation Handbook, the AquaSAFE™ Fire Safety Installation Guide or the Uponor Radiant Installation Handbook.
Listings
2
cNSFus-fs
3
; cNSFus-pw; cNSFus-rfh; cQAIus; UL; CSA; WH; ETL; PPI TR-4; ICC-ES; IAPMO; BMEC; CCMC
Codes
ICC; IPC; IMC; IRC; UPC; UMC; NSPC; HUD; UFGS; NPC of Canada; NBC of Canada
Standards
ANSI/NSF 14; ANSI/NSF 61; ASTM F876; ASTM F877; ASTM F1960; ASTM F2023; ASTM E84; CAN/ULC S102.2; ASTM E119/UL 263;
CAN/ULC S101; ASTM E814/ULC S115; AWWA C904
4
; CSA B137.5; CSA B214; UL 1821
3
; ULC/ORD-C199P
3
Related Applications
Contact Information
PEX-a Plumbing Systems
Radiant Heating and Cooling Systems
AquaSAFE Fire Safety Systems
Uponor, Inc.
5925 148
th
Street West
Apple Valley, MN 55124 USA
Phone: 800.321.4739
Fax: 952.891.2008
www.uponorpro.com
Uponor Ltd.
2000 Argentia Road, Plaza 1, Suite 200
Mississauga, ON L5N 1W1 CANADA
Phone: 888.994.7726
Fax: 800.638.9517
www.uponorpro.com