User Guide
52 l uponorengineering.com
Uponor Logic plumbing
Uponor Logic is the smart way to plumb, using exible Uponor PEX pipe and multiport tees to minimize connections and maximize
system performance. With an Uponor Logic layout, plumbing systems typically require fewer ttings than a trunk and branch design
and less pipe than a home run layout.
Uponor Logic
Number of fittings 9
Number of connections 33
Nominal pipe size Length (ft.)
½" 261
¾" 38
1" 5
Total 304
Table 5-1: Uponor Logic pipe and ttings usage
Home run
Number of fittings 7
Number of connections 27
Nominal pipe size Length (ft.)
½" 475
¾" 30
1" 5
Total 510
Table 5-2: Home run pipe and ttings usage
½" TYP
1" CW SUPPLY
½"
¾"
½" TYP
1" CW SUPPLY
¾"
Uponor
Logic
layout
Home
run
layout
Figure 5-3: Uponor Logic layout Figure 5-4: Home run layout
Critical path = HWS — W.H. to tub UPC tub = 4 wsfu = 4 gpm
CWS = 60°F HWS = 120°F Mixed = 110°F Hot-water multiplier = 0.83 = 3.32 gpm
System
type
I.D. (in.)
Distance
(ft.)
Volume (gal.)
Velocity
(ft./sec.)
Pressure loss (psi)
First-use
HW time to fixture
½" ¾" ½" ¾" ½" ¾" Total ½" ¾" ½" ¾" Total Critical path (tub only)
Copper T&B 0.527 0.745 13 33 0.147 0.746 0.893 4.8 2.43 1.22 0.561 1.781 16.1 sec.
Home run 0.475 0.671 32 9 0.294 0.165 0.459 5.8 3 4.16 0.252 4.412 8.3 sec.
Uponor Logic 0.475 0.671 19 17 0.174 0.312 0.486 5.8 3 2.47 0.476 2.946 8.7 sec.
Table 5-3: Performance comparisons