User Guide
Plumbing Design Assistance Manual l Chapter 3 – Fire-resistant construction l 31
CAN/
ULC-S102.2
— surface
burning characteristics
As dened by the National
Building Code of Canada
(NBCC), combustible
piping may be installed
in areas required to be of
noncombustible construction,
provided the piping is installed
in a wall or concrete-oor slab
or the pipe has a ame-spread
(FS) index rating of not
more than 25 and a smoke-
developed (SD) index rating
of not more than 50 when
tested in accordance with
CAN/ULC-S102.2.
Uponor PEX-a piping systems
comprised of Uponor PEX-a
piping, Uponor ProPEX rings,
Uponor EP ttings, Uponor
LF brass ttings and Uponor
PEX-a pipe support products
are listed for installation in
return-air plenums as
tested in accordance with
CAN/ULC-S102.2.
The below listings apply to
Uponor PEX-a piping systems
installed in either horizontal
or vertical orientations in the
eld. Refer to Table 3-4 for
installation requirements.
QAI P321-1
½" Uponor PEX-a
(Uninsulated)
Adjacent runs of un-insulated
½" Uponor PEX-a piping in
a return-air plenum have no
spacing limitations.
¾" and 1" Uponor PEX-a
(Uninsulated)
Adjacent runs of uninsulated
¾" and 1" Uponor PEX-a
piping must be separated by
18".
QAI P321-1
Up to and including 3"
Uponor PEX (insulated)
Uponor PEX piping
manufactured with a maximum
nominal OD of 3" and encased
in ½" insulation in accordance
with Table 3-5 shall have no
limitation on spacing.
QAI P321-3
Up to and Including 2"
Uponor PEX-a (Water-lled,
Uninsulated)
Adjacent runs of water-lled,
uninsulated piping in a return-
air plenum have a no spacing
limitations.
Classified as to surface burning characteristics
CAN/ULC S102.2 Flame spread Smoke developed Limitations
½" nominal size 25 or less 50 or less No spacing limitations.
¾" and 1" nominal sizes 25 or less 50 or less Adjacent pipe runs shall be
located at least 18" apart.
2" maximum nominal size
(water-filled)
25 or less 50 or less No spacing limitations.
3" maximum nominal size
Uponor PEX-a with ½" insulation
25 or less 50 or less ½" minimum thickness insulation
as specified in Table 3-5.
Table 3-4: Uponor AquaPEX CAN/ULC-S102.2 requirements