Installation guide

Uponor Climate Co˘ntrol™ Zoning System Installation Guide
45
Component Alarms/Issues Causes Solutions Notes
Base Unit • System does not start.
• Power LED off
No voltage Ensure base unit powered
correctly.
Base Unit
and Antenna
• Poor radio reception Antenna mounted inside
metal cabinet
Antenna out of position
or wire disconnected
• Interference
Change the location of the
antenna.
Power LED and channel
LED blink
Short circuit on a
connected actuator
Short circuit on the
actuator terminal/wiring
error
Use another channel (if an
unused one is remaining).
For replacement of the
base unit, see Section 3.
See Installation Report to
contact an installer.
Thermostat
Display T-75
Battery icon displayed Thermostat batteries
getting low
• Replace the batteries. When the error is
resolved, the thermostat
screen displays the room
temperature and the battery
icon
disappears.
Display is off Batteries dead or wrong
type.
Batteries installed
incorrectly.
• Replace the batteries.
Radio transmission icon
is displayed, but the
channel status (LED on/
off) changes only if the
thermostat is close to the
antenna.
Transmitter working,
but with reduced signal
intensity
New installations in the
house create interference.
• Contact an installer.
Find a new position
for thermostat and/
or antenna to prevent
interference.
Table 10-1: Troubleshooting Solutions