Overview of Primary Product

Loading Staples
1. Grasp stapler at the bottom of the staple guard minimum feed line and tip
upsidedown.
2. The staple weight will slide out of the staple guard. Place the weight in the
weight holder.
3. Place staples in the staple guard.
Note: Ensure the amount of staples does not fall below the minimum
feed line.
4. Slide the staple weight off the stop and slide in the staple guard.
Securing Uponor PEX to Foam Insulation
1. Grasp the stapler by the handle (ensure it is upright) and align the grove in
the base of the stapler over the tubing.
2. Push down on the handle using a firm, smooth stroke.
3. Install staples every three feet. For loops or bends in tubing, install
staples in the center of the bend and a minimum of one staple at each
end of the bend.
Clearing a Jammed Staple
1. Slide the jam door lock up and open the jam door (see Figure 2).
2. Remove the jammed staple from the feed tube (see Figure 3).
3. Close the jam door and slide the jam door lock down.
Replacement Parts List
Part No. Part Description
E6025000 PEX Foam Stapler
A7012000 2" Blue Foam Staples, 300/pkg.
E6025001 PEX Foam Stapler Handle, replacement part
E6025002 PEX Foam Stapler Jam Door, replacement assembly
E6025003 PEX Foam Stapler Spring, replacement part
E6025004 PEX Foam Stapler Metal Stand, replacement assembly
E6025005 PEX Foam Stapler Shear Plate, replacement part
Uponor, Inc.
5925 148th Street West
Apple Valley, MN 55124 USA
Tel: 800.321.4739
Fax: 952.891.2008
Uponor Ltd.
2000 Argentia Rd., Plaza 1, Ste. 200
Mississauga, ON L5N 1W1 CANADA
Tel: 888.994.7726
Fax: 800.638.9517
PEXFoamStapler_IS_H496_0614, Copyright © 2014 Uponor. Printed in the United States
www.uponorpro.com
Figure 2: Open the Jam Door
Figure 3: Remove the Jammed Staple