Replacement Parts List

Uponor Radiant Heating and Cooling Systems
www.uponor.ca (888) 994-7726 Radiant Heating and Cooling Systems
Radiant Heating and Cooling Systems
29
The Network Furnace and Air Condition (FAC) Control board provides control of Fan, Air Heat, Cooling,
Humidifi cation and Dehumidifi cation functions. This device is used for operation of air handlers, furnaces
and rooftop units. The FAC has two additional contacts for 10K sensors for additional system feedback.
All connections are screw terminals blocks and are removable from the board for ease of wiring. The board
comes with a manual switch that can be set in the Off-Auto-Manual positions. The FAC requires 24VAC and
communicates with the Router Main Control over Cat5 wire and RJ45 connectors.
Part No. Part Description Each Qty.
A9011100 Furnace and Air Condition Control (FAC) 1
The Network Heat Recovery Ventilator (HRV) Control board provides control of up to three speeds of
operation: Low, Medium and High. All connections are screw terminals blocks and are removable from the
board for ease of wiring. The board comes with a manual switch that can be set in the Off-Auto-Manual
positions. The HRV communicates with the Router Main Control over Cat5 wire and RJ45 connectors along
with power for the board.
Part No. Part Description Each Qty.
A9011200 Heat Recovery Ventilator Control (HRV) 1
A9010201 VOC-CO2 Indoor Air Quality Sensor, optional 1
The Network Zone Valve Damper (ZVD) Control provides control of up to eight zone valves or zone
dampers for On-Off operation. All connections are screw terminals blocks and are removable from the
board for ease of wiring. Jumper pins on the board can be set for dry contact or powered switching along
with address number and device type (valves or dampers). The board comes with a manual switch that can
be set in the Off-Auto-Manual positions. The Zone Valve Damper Control (ZVD) communicates with the
Router Main Control over Cat5 wire and RJ45 connectors and requires a 24VAC power source.
Part No. Part Description Each Qty.
A9011400 Zone Valve and Damper Control (ZVD) 1
The Network Generic Input/Output (GIO) board provides control of up to eight low-voltage devices for
On-Off operation along with detecting eight switched inputs. All connections are screw terminals blocks
and are removable from the board for ease of wiring. Jumper pins on the board can be set for dry contact
or powered switching along with address number and device type. The board comes with a manual switch
that can be set in the Off-Auto-Manual positions. The GIO board communicates with the Router Main
Control over Cat5 wire and RJ45 connectors and requires a 24VAC power source.
Part No. Part Description Each Qty.
A9011600 Network Generic Input/Output (GIO) 1
The Climate Co˘ntrol Network System features a series of Network Device Controls, specifi c for the
equipment the network will control. Each control connects with the main panel controllers over a Cat5 wire
and RJ45 connectors. Connection points inside the panel will depend on the function it serves. Inside each
enclosure, a switch is provided for Auto and Manual operation. LEDs on the case provide feedback to the
mode of operation and if the device is wired correctly. Each control has a ³⁄₄" thread for mounting directly
to the equipment or to a standard electrical box knockout. The Variable Speed Pump Control requires a
pump that will accept a 0-10VDC control signal.
Part No. Part Description Each Qty.
A9012010 Boiler Relay, On-Off 1
A9012020 Boiler Relay, Modulating 0-10VDC 1
A9063020 Modulating Valve Control, 0-10v 1
A9013030 Pump Relay, On-Off 1
A9013040 Network Variable Speed Pump Control, Modulating 0-10VDC 1
Network Furnace and Air
Condition Control (FAC)
Network Heat Recovery
Ventilator Control (HRV)
Network Zone Valve Damper
Control (ZVD)
Network Generic Input/
Output (GIO) Control
Network Relay