Product Overview
Frequently asked questions
How is this thermostat different from
Uponor’s current control offering?
With the A3100101 Uponor Heat-only
Thermostat with Touchscreen, we took the best
features of the A3030101 Uponor
Heat-only Thermostat and made it better.
We took the control and reliability you have
come to trust with the Heat-only Thermostat
and transferred it to a sleek, new version that
includes a simple, easy-to-use touchscreen.
The slim design ts today’s installation
aesthetic requirements, and it also allows
connection of a oor sensor to further enhance
the offering.
Will this be replacing any of
Uponor’s current products?
Uponor will be eliminating the following
products.
• Heat-only Thermostat (A3030101)
• SetPoint 501, Single-stage SetPoint
Controller (A3040501)
• SetPoint 501s, Single-stage SetPoint
Controller with Floor Sensor (A3041501)
The following products will remain
in our offering.
• Heat and Cool Thermostat (A3030102)
• SetPoint 511s, Single-stage Programmable
Controller with Floor Sensor (A3041511)
• SetPoint 511s, Single-stage Programmable
Controller with Floor Sensor (A3041511)
What are the different modes
of the thermostat?
The Uponor Heat-only Thermostat with
Touchscreen can operate a radiant heating
system based on the air sensor measure
operative temperature, a oor sensor, or a
combination of both to provide the optimal
level of comfort and control.
• Air temperature only: When a oor
sensor is not connected, the thermostat
will maintain the room’s air temperature
based on the desired temperature setting.
• Air and oor: If using both sensors,
the thermostat will maintain the room air
temperature along with maintaining a
minimum oor temperature. Early in the
heating season when the room is not
experiencing high loads, it may be desirable
to have a warmer oor. The oor setpoint can
be adjusted to maintain the oor temperature.
When the outdoor temperature drops and the
room load increases, the air sensor will take
over. This maintains the air temperature and
provides a warm oor.
• Floor sensor only: The air sensor can
be disabled or turned off should the
application require it (e.g., bathrooms).
In this instance, the thermostat will only
maintain the oor temperature.
What is operative temperature sensing?
Operative temperature is what people
experience thermally in a space by combining
the effects of air temperature, air speed and
thermal radiation. This provides superior control
of a radiant heating system while maximizing
comfort and efciency. The design of the
thermostat closely senses room conditions in
the same manner as the human body.
Uponor, Inc.
5925 148th Street West
Apple Valley, MN 55124
USA
T 800.321.4739
F 952.891.2008
Uponor Ltd.
2000 Argentia Rd., Plaza 1, Ste. 200
Mississauga, ON L5N 1W1
CANADA
T 888.994.7726
F 800.638.9517
A3100101_Uthermostat_SellSheet_69298_0416, Copyright © 2016 Uponor. Printed in the United States.
uponorpro.com