Operation Manual

7
8
Press the tabs to open
the thermostat.
21
22
Back-Cover
Wall
Through Hole
Wires
Wall
Wi res
Back-Cover
Te r mina l s
Figure 1
LEVEL
Mark the locations
with a pencil
Back-Cover
+
+
++
++
++
++
++
++
++
++
++
++
++
Repeat the procedures for weekday program 3 and 4, and similarly for Saturady programs (P1 - P4)
and Sunday programs (P1 - P4)
After complete setting of all 12 programs,
if you have the THM302M, press PROG to return to normal display (SET PROGRAM symbol
will disappear).
If you have the THM303M, press PROG once will take you to humidity setting (seeing Humidifier
Control) or press PROG twice to return to normal display.
Note:
The PROG key can also be used
anytime to review all the set programs.
To terminate the programming
sequence at anytime, press
DISPLAY key.
Tip:
Press and hold the AHEAD/BACK or
UP/DOWN key to change the numbers
quickly.
Cooling Programs
Slide the system switch to the COOL position and repeat the programming as you would for the Heating Programs.
Note: The Humidifier Control (THM303M) only functions in HEAT mode.
Temporary Override
To change the temperature temporarily, press UP or DOWN to set the desired temperature. The OVERRIDE
symbol will appear. The thermostat will return to the regular program at the next scheduled program time.
Note: The thermostat has an automatic delay function to protect the heating and cooling systems from
undesired on/off sequences. Sometimes there will be a delay of several minutes before the thermostat
will activate the system.
Hold
This feature is to hold the thermostat at a constant temperature and disable all set programs until released.
Press HOLD once and use UP or DOWN button to set the desired hold temperature. HOLD symbol will
appear to indicate that the Hold function is active.
To cancel Hold function, press HOLD again. The HOLD symbol will disappear and the thermostat will
return to the programmed temperature.
Mounting The Thermostat Back-Cover
The back-cover should be mounted horizontally with
the terminals on the left side.
Thread the existing wiring through the big center hole
from the back and set the back-cover horizontally on
the wall.
Select two appropriate mounting holes and mark the
locations with a pencil. If necessary, use a level to make
sure the thermostat is leveled.
Remove the back-cover from the wall and drill two 3/16
inch holes in the marked screw positions. Insert the
wall-anchors into the holes completely. If necessary,
use a hammer to tap-in lightly.
Mount the back-cover with the two screws to the wall.
Make sure the metal terminals are on the left side.
Connecting The Wires To The Terminals
Connect the previously labeled wires to the corresponding
terminals, matching the designations. Use a screwdriver to
securely fasten the wires onto the terminals. Make sure the
wires do not short-circuit with other terminals.
Depending on your heating/cooling equipment, you may
need to connect 2 to 9 wires to the thermostat.
If you have two ‘R’ wires, then connect each wire to its
corresponding terminal and remove the JUMPER between
the RC and RH terminals.
If you are unsure of the connections, or for new installation,
you may refer to the wiring diagrams on the next page:
1
2
3
4
5
6