User manual
Table Of Contents
- About This Manual
- 1 VLAN Configuration
- VLAN Overview
- Configuring VLAN
- Creating VLAN
- Creating a VLAN in VLAN Database
- Setting VLAN Name
- Setting VLAN Link Type on Ethernet Interface
- Adding VLAN Member Port
- Adding Ports to a VLAN in Batches
- Setting the Native VLAN for a Trunk or Hybrid Port
- Setting VLAN Filtering on a Port
- Setting Frame Filtering Type of a Port
- Creating VLAN Layer 3 Interface
- VLAN Configuration Example
- Configuring PVLAN
- Configuring QinQ
- Configuring Subnet VLAN
- Configuring Protocol VLAN
- Configuring VLAN Translation
- Configuring SuperVLAN
- VLAN Maintenance and Diagnosis
- 2 SVLAN Configuration
- 3 SVLAN COS Configuration
- 4 ZESR and SVLAN Linkage Networking Configuration
- 5 MAC Address Table Configuration
- Introduction to MAC Address
- Configuring MAC Address Table
- Setting MAC Address Aging Time
- Burning MAC Addresses
- Configuring MAC Address Permanent
- Binding MAC Address to a Port
- Enabling MAC Address Learning
- Limiting MAC Address Count
- Setting MAC Address Learning Protection
- Setting Port Unkown Source MAC Address Filtering
- Setting MAC Address Filtering
- Viewing MAC Address Table
- MAC Address Table Configuration Example
- 6 STP Configuration
- 7 Link Aggregation Configuration
- 8 IGMP Snooping Configuration
- 9 Sflow Configuration
- 10 ZESS Configuration
- 11 Ethernet OAM Configuration
- 12 UDLD Configuration
- 13 LLDP
- 14 L2PT Configuration
- Figures
- Tables
- Glossary

Chapter3
SVLANCOS
Configuration
TableofContents
SVLANCOSOverview.........................................................23
ConguringSVLANCOS......................................................23
SVLANCOSCongurationExample......................................24
SVLANCOSMaintenanceandDiagnosis................................24
SVLANCOSOverview
InSVLANQinQmode,whenreceivingtaggeddatapacketfrom
usertrunkport,uplinkportreservestheoriginaldatapackettag
andattachesserviceprovidertag.Thistagincludes2bytesEth-
ernettype(0x8100)and2bytespriorityandVID,inwhichpriority
eldis3bitsandthiseldisCOS,wecallthisasservicetype,ser-
vicelevel.Orservicepriority.ThefunctionistocongureCOS
priorityvalue.
ConfiguringSVLANCOS
Step
CommandFunction
1
ZXR10(config)#cos-session<session_id>[cos0
<0-7>],[cos1<0-7>],[cos2<0-7>],[cos3
<0-7>],[cos4<0-7>],[cos5<0-7>],[cos6
<0-7>],[cos7<0-7>]
ThisconguresSVLANCOS.
session-id<1-16>
Thisconguresacosonetime
ormanycoses.
2
ZXR10(config)#interface<port-name>Thisentersinterface
congurationmode.
3
ZXR10(config-gei_1/x)#cos-modecos-map-session
<session_id>
Thisappliessession
correspondingcostophysical
interface.
4
ZXR10(config)#nocos-session<session_id>ThisdeletesSVLANCOS
conguration.
5
ZXR10(config-gei_1/x)#nocos-modecos-map-ses
sion<session_id>
Thisdeletesthebindingof
sessiononphysicalport.
CondentialandProprietaryInformationofZTECORPORATION23