LinkMonitor
Linkmonitorfunctionistodostatisticsforfaultsymbolsorfault
framesthatphysicallayerreceivesduringxedtime.Thedriver
hasacounterwhichisalwaysdoingthestatisticsoffaultframe,
faultsymbol,andtotalreceivingframenumber .Theplatform
readstheseinformationatspecictime,thenjudgeandprocess
accordingtofaultsymbolnumber ,faultframenumberandtotal
framenumber ,detectwhatkindofeventhappensandgenerate
thecorrespondingeventtoinformOAMPDU.
Therearefourtypesoflinkevent:
1.Linkfaultsymbolperiodevent,countthefaultsymbolgener-
atedinspecictime.Periodisdenedbysymbolsnumberthat
physicallayerreceivesinsometime.
2.Faultframeevent,countthefaultframegeneratedinspecic
time.
3.Faultframeperiodevent,countthefaultframegeneratedin
specictime.Theperiodisdenedbyreceivingframenumber .
4.Faultframesecondaccumulatedevent,countthefaultframe
secondgeneratedinspecictime.Periodisdenedbytime
interval.
Configuring802.3ah
FunctionConfiguration
Step
CommandFunction
1
ZXR10(config)#setethernet-oam{enable|disable}ThisenablesEthernet-OAMin
globalcongurationmode.
Enable:opengloballink
Ethernet-OAMfunction.
Disable:closegloballink
Ethernet-OAMfunction.
2
ZXR10(config)#setethernet-oam<oui>
ThissetsOUIofEthernet
OAM.
<oui>ischaracterstring
type,themaximumlengthen
is3.
3
ZXR10(config)#setethernet-oamremote-loopback
timeout<1-10>
ThissetsEthernetOAM
remote-loopbacktimeout
interval.
Theunitof<1-10>issecond.
Ifthefunctionisnotset,the
defaultvalueis3.
CondentialandProprietaryInformationofZTECORPORATION91