Instructions / Assembly

16
TROUBLESHOOTING
Sudden drop in gas flow, or a
reduced flame height
Irregular flame pattern, flame does
not run the full length of the burner
Flame blow out
High or gusting winds
Increase flame to HIGH setting.
Replace or refill LP gas tank.
Refer to Problem: Sudden drop in gas flow.
Turn the control knob and the LP gas tank to OFF. Replace with
a spare LP gas tank and resume burning. Store the spare LP
gas tank in a well ventilated area, away from children.
Low on LP gas
Excess flow valve tripped
Ice has built up on the outside of t-
he LP gas tank because the vapo-
rization process is too low
Flame seems to lose heat when
burning in cold weather - tempera-
ture below 50°F
Burner ports are clogged or
blocked
Clean burner ports. Do this by inserting a paperclip into each of
the burner ports to ensure they are not clogged.
WARNING: Make sure burner is not on, and has had sufficient
time to cool before touching it.
Out of Gas
Check for gas in the LP gas tank
Excess flow safety device may
have been activated
Turn control knob to OFF, wait 30 seconds and light outdoor fire
table. if flames are still too low, reset the excessive flow safety
device by turning off the control knob and LP gas tank valve.
Disconnect regulator. Turn burner control knob to HIGH. Wait at
least 5 minutes. Turn burner control knob off.
Reconnect regulator and perform a leak check at tank connec-
tion. Turn LP gas tank valve on slowly, wait 30 seconds and
then light outdoor fire table.