Instructions / Assembly
13
TROUBLESHOOTING
Problem: Burner JUST LIGHT UP FOR SECOND AND WILL AUTOMATICALLY TURN OFF
Resetting Your Gas Valve
1. The thermocouple will be under the Pilot Guard on the top of the unit. Please remove
the Pilot guard by unscrewing it from the metal bowl with a screw driver .
2. Once the Pilot Guard has been removed, you will have two components exposed; the
copper one is your thermocouple. Please unscrew the nut holding the thermocouple in
place.
3. Inside the unit, you will notice that the end of the thermocouple line is directly screwed
to the gas valve. Please unscrew the thermocouple from the back end of the gas valve.
Do not take off the valve's silver backing, only unscrew the small nut as shown above.
4. Screw the end of the thermocouple to the back end of the gas valve with the silver
backing.
Once this has been done, lease test the unit. You may have to reset the gas valve once
again as the safety mechanism may have been set off by the new components introduced:
Completely detach the propane tank from the table. Do not forget to turn the propane tank valve down. Turn the heat knob to high and leave it on that
setting for about two to three minutes.
Once you have done this, please turn the knob back to off. Hook up the propane tank and turn the propane tank's valve a quarter of a turn at a time.
NOTE: When reattaching the propane tank, please turn the valve to release the gas back in to the unit VERY SLOWLY. We want the unit to register
gas coming through but not too much at once, this will flood the unit and you will have to start all over!
This is so that the gas valve can register the gas coming through a little at a time. Once you have turned the gas on all the way please go ahead and try
to light the table again. This should reset your fire table's safety mechanism