Instructions / Assembly

11
TROUBLESHOOTING
Burner will not light using igniter
Burner will not light with match
The fire table emits a lot of black
smoke when in use
Hose from gas fire table is pinched
Make sure the hose is not pinched between the fire table and the
source of the gas.
Make sure that the gas ports on the burner are free of any lava
rocks / fire glass so that the flame can flow naturally. Clear out
the mixing chamber located before the Venturi.
Flame is being obstructed at bur-
ner ports or mixing chamber of the
burn tube is blocked or obstructed
Electrode and burners are wet Wipe dry with cloth.
Check that the AA battery is inserted correctly in the igniter or
replace the battery. Make sure the plastic wrap on the battery has
been removed.
Please contact UPHA to request the parts.
Check for residue on the igniter pin or Thermocouple. If dirty,
thoroughly clean the area. Check that the electronic Ignitor Cap
is tightly fitted to the spring. If loose, please adjust the spring
accordingly.
Igniter battery is dead or back-
wards
Igniter Pin cracked or broken-
sparks a crack
Residue on Igniter Pin
No Gas Flow
Check if the LP gas tank is empty. If empty, replace and refill.
If the propane tank is not empty, refer to Problem: Sudden drop
in gas flow on the following page.
Turn the coupling nut about one half to three fourths a turn, until
you feel a solid stop. Do not use tools, tighten by hand only.
Obstruction of gas flow
Check for bent or kinked hose.
Clean the venturi.
Reference Problem: Irreqular flame pattern on the following page.
Clean the burner ports as described there.
Spider webs or insect nest in the
venturi
Burner ports clogged or blocked
Coupling nut and regulator not
fully connected